Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins

文献类型:期刊论文

作者Wang YaRong; Li JingJing; Wu ZhiYong; Fan JunGang; Fang Fang
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
出版日期2008
卷号36期号:7页码:879-884
关键词ZONE-ELECTROPHORESIS ELECTROKINETIC CHROMATOGRAPHY SENSITIVITY ENHANCEMENT ETCHED JOINT STACKING SYSTEM SEPARATION INTERFACE PEPTIDES capillary electrophoresis porous conductive membrane injection pre-concentration lysozyme bovine serum albumin ultraviolet detection
ISSN号0253-3820
其他题名Improvement of Porous Electro-conductive Membrane Preparation and Its Application in Sample Injection Pre-concentration in Capillary Electrophoresis of Proteins
英文摘要The success rate of porous conductive membrane preparation on fused silica capillary was greatly improved by control of voltage bias and electroosmosis effect. Basic buffer media was filled into the column, and a direct curvent voltage was applied between the capillary inlet and the etching reservoir during the etching process. The etching was stopped due to electroosmosis effect when electro-conductivity of the etching membrane occurred, and over etching was automatically avoided. The conductive membrane prepared was successfully used in on-line sample electro injection pre-concentration and capillary electrophoresis separation of model proteins of lysozyme and bovine serum albumin in 0.05 mol/L pH 2.50 Tris-H, PO, with 2% - 4% dextran, and a concentration factor close to the theoretical value was obtained. The difference of concentration factors for basic and acidic proteins was discussed. Detection limits for the model proteins were decreased to 1 x 10(-11) mol/L with a routinely used photometric detector (214 nm wavelegnth) by electro-injection pre-concentration for 30 min.
语种英语
CSCD记录号CSCD:3333224
源URL[http://ir.imr.ac.cn/handle/321006/146267]  
专题金属研究所_中国科学院金属研究所
作者单位中国科学院金属研究所
推荐引用方式
GB/T 7714
Wang YaRong,Li JingJing,Wu ZhiYong,et al. Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2008,36(7):879-884.
APA Wang YaRong,Li JingJing,Wu ZhiYong,Fan JunGang,&Fang Fang.(2008).Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,36(7),879-884.
MLA Wang YaRong,et al."Improvement of porous electro-conductive membrane preparation and its application in sample injection pre-concentration in capillary electrophoresis of proteins".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 36.7(2008):879-884.