Simultaneous detection of hydrogen sulfide and carbon dioxide based on off-axis integrated cavity output spectroscopy using a near-infrared distributed feedback diode laser
文献类型:期刊论文
作者 | Tian, Xing1,2; Cheng, Gang1,2; Cao, Yanan1,2; Chen, Jiajin3; Liu, Kun3![]() ![]() |
刊名 | MICROWAVE AND OPTICAL TECHNOLOGY LETTERS
![]() |
出版日期 | 2021-05-17 |
关键词 | Allan variance carbon dioxide hydrogen sulfide off‐ axis integrated cavity output spectroscopy simultaneous detection |
ISSN号 | 0895-2477 |
DOI | 10.1002/mop.32887 |
通讯作者 | Gao, Xiaoming(xmgao@aiofm.ac.cn) |
英文摘要 | An optical scheme for simultaneous detection of hydrogen sulfide (H2S) and carbon dioxide (CO2) is demonstrated. A near infrared tunable diode laser operating at 1.578 mu m including the absorption lines of H2S at 6336.62 cm(-1) and CO2 at 6336.24 cm(-1) was used as the light source for spectroscopic measurements of H2S and CO2. A high-finesse cavity with a base length of 21 cm and a pair of high reflectivity mirrors with a reflectivity of 99.999% were employed based on off-axis integrated cavity output spectroscopy. Allan variance analysis shows that the minimum detection limits of 150 ppbv for H2S in 170 s averaging time and 1.03 ppmv for CO2 in 209 s, respectively. |
WOS关键词 | H2S ; SPECTROMETER ; SENSOR ; CO2 |
资助项目 | National Key Research and Development Program of China[2017YFC0209700] ; Natural Science Research Project of Anhui Universities[KJ2020A0290] ; National Natural Science Foundation of China[41730103] ; National Natural Science Foundation of China[61775221] ; Youth Innovation Promotion Association of Chinese Academy of Sciences[2015263] |
WOS研究方向 | Engineering ; Optics |
语种 | 英语 |
WOS记录号 | WOS:000651124400001 |
出版者 | WILEY |
资助机构 | National Key Research and Development Program of China ; Natural Science Research Project of Anhui Universities ; National Natural Science Foundation of China ; Youth Innovation Promotion Association of Chinese Academy of Sciences |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/122417] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Gao, Xiaoming |
作者单位 | 1.Anhui Univ Sci & Technol, State Key Lab Min Response & Disaster Prevent & C, Huainan, Peoples R China 2.Anhui Univ Sci & Technol, Sch Artificial Intelligence, Huainan, Peoples R China 3.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China |
推荐引用方式 GB/T 7714 | Tian, Xing,Cheng, Gang,Cao, Yanan,et al. Simultaneous detection of hydrogen sulfide and carbon dioxide based on off-axis integrated cavity output spectroscopy using a near-infrared distributed feedback diode laser[J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS,2021. |
APA | Tian, Xing,Cheng, Gang,Cao, Yanan,Chen, Jiajin,Liu, Kun,&Gao, Xiaoming.(2021).Simultaneous detection of hydrogen sulfide and carbon dioxide based on off-axis integrated cavity output spectroscopy using a near-infrared distributed feedback diode laser.MICROWAVE AND OPTICAL TECHNOLOGY LETTERS. |