Angular stability measurement of a cryocooled double-crystal monochromator at SSRF
文献类型:期刊论文
作者 | Fan, YC; Qin, HL; Zhu, WQ; Jia, WH; Liu, Y; Wang, J; Li, ZL |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
出版日期 | 2020 |
卷号 | 983页码:- |
ISSN号 | 0168-9002 |
DOI | 10.1016/j.nima.2020.164636 |
文献子类 | 期刊论文 |
英文摘要 | Precisely measuring the angular stability is essential to evaluate and improve the performance of the double-crystal monochromator (DCM). Herein, we apply a non-contact high-precision angular measurement method by utilization of the interferometers instead of conventional capacitive sensors, realizing a high resolution of picometer scale; particularly, a large working range of tens of millimeters can be simultaneously achieved, superior to previous method. By this means, we systematically investigate a homemade cryo-cooled DCM at Shanghai Synchrotron Radiation Facility (SSRF). The temporal stability as well as main eigen-frequencies of the DCM mechanics are measured at ambient temperature (25 degrees C) and under liquid nitrogen (LN2) cooling condition, respectively. Fast Fourier Transform (FFT) analysis of these data hints possible vibration sources. Accordingly, flexible tube with an alumina fiber textile inner is adopted and the support of the cooling lines is optimized. Furthermore, relative vibrations with different cryo-cooler settings are compared, revealing a slightly enhanced amplitude with increasing flow rate. Through these optimizations, the DCM achieves a vertical stability of 125 nrad RMS in 1 similar to 100 Hz and 180 nrad RMS in 1 similar to 1000 Hz over the full photon energy, which meets the requirement of the Fast X-ray Imaging beamline at SSRF. |
语种 | 英语 |
源URL | [http://ir.sinap.ac.cn/handle/331007/32705] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
作者单位 | 1.Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China 2.Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China 3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Fan, YC,Qin, HL,Zhu, WQ,et al. Angular stability measurement of a cryocooled double-crystal monochromator at SSRF[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2020,983:-. |
APA | Fan, YC.,Qin, HL.,Zhu, WQ.,Jia, WH.,Liu, Y.,...&Li, ZL.(2020).Angular stability measurement of a cryocooled double-crystal monochromator at SSRF.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,983,-. |
MLA | Fan, YC,et al."Angular stability measurement of a cryocooled double-crystal monochromator at SSRF".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 983(2020):-. |
入库方式: OAI收割
来源:上海应用物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。