中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy

文献类型:期刊论文

作者Han, RC; Li, YJ; Pu, YH
刊名NUCLEAR SCIENCE AND TECHNIQUES
出版日期2020
卷号31期号:2页码:-
关键词ION RECOMBINATION CORRECTION REFERENCE DOSIMETRY SYSTEM
ISSN号1001-8042
DOI10.1007/s41365-020-0722-z
文献子类期刊论文
英文摘要The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems. Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems. In this study, Boag's theory was applied to a proton pencil beam scanning system. The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area. This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency. It was determined that collection efficiency is positively correlated with applied voltage, beam size, and beam energy, but negatively correlated with beam current intensity. Additionally, it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen.
语种英语
源URL[http://ir.sinap.ac.cn/handle/331007/32749]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
作者单位1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
2.Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
3.Shanghai APACTRON Particle Equipment Co Ltd, Shanghai 201800, Peoples R China
4.Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
推荐引用方式
GB/T 7714
Han, RC,Li, YJ,Pu, YH. Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy[J]. NUCLEAR SCIENCE AND TECHNIQUES,2020,31(2):-.
APA Han, RC,Li, YJ,&Pu, YH.(2020).Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy.NUCLEAR SCIENCE AND TECHNIQUES,31(2),-.
MLA Han, RC,et al."Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy".NUCLEAR SCIENCE AND TECHNIQUES 31.2(2020):-.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。