中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Evaluation of plan quality and robustness of IMPT and helical IMRT for cervical cancer

文献类型:期刊论文

作者Shang, HJ; Pu, YH; Wang, W; Dai, ZT; Jin, F
刊名RADIATION ONCOLOGY
出版日期2020
卷号15期号:1页码:-
关键词MODULATED PROTON THERAPY TREATMENT UNCERTAINTIES PELVIC RADIOTHERAPY RADIATION-THERAPY OPTIMIZATION VOLUME SENSITIVITY REDUCTION RANGE HEAD
ISSN号1748-717X
DOI10.1186/s13014-020-1483-x
文献子类期刊论文
英文摘要Background Both plan quality and robustness were investigated through comparing some dosimetric metrics between intensity modulated proton therapy (IMPT) and helical tomotherapy based intensity modulated radiotherapy (IMRT) for cervical cancer. Methods Both a spot-scanning robust (SRO) IMPT plan and a helical tomotherapy robust (TRO) IMRT plan were generated for each of 18 patients. In order to evaluate the quality of nominal plans without dose perturbations, planning scores (PS) on clinical target volume (CTV) and five organs at risk (OARs) based on clinical experience, and normal tissue complication probabilities (NTCP) of rectum and sigmoid were calculated based on Lyman-Kutcher-Burman (LKB) model. Dose volume histogram bands width (DVHBW) were calculated in 28 perturbed scenarios to evaluate plan robustness. Results Compared with TRO, the average scores of SRO nominal plans were higher in target metrics [V-46.8Gy, V-50Gy, Conformity and Homogeneity](16.5 vs. 15.1), and in OARs metrics (60.9 vs. 53.3), including bladder [V-35,V-45, D-mean,D-2cc], rectum [V-40,V-45,D-2cc,D-max], bowel [V-35,V-40,V-45, D-max], sigmoid [V-40,D-max] and femoral heads [V-30,D-max]. Meanwhile, NTCP calculation showed that the toxicities of rectum and sigmoid in SRO were lower than those in TRO (rectum: 2.8% vs. 4.8%, p < 0.05; sigmoid: 5.2% vs. 5.7%, p < 0.05). DVHBW in target coverage for the SRO plan was smaller than that for the TRO plan (0.6% vs. 2.1%), which means that the SRO plan generated a more robust plan in target. Conclusion Better CTV coverage and OAR Sparing were obtained in SRO nominal plan. Based on NTCP calculation, SRO was expected to allow a small reduction in rectal toxicity. Furthermore, SRO generated a more robust plan in CTV target coverage.
语种英语
源URL[http://ir.sinap.ac.cn/handle/331007/32863]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
作者单位1.Shanghai Jiao Tong Univ, Sch Med, Xinhua Hosp, Dept Radiat Oncol, Shanghai, Peoples R China
2.Chongqing Canc Hosp, 181 Hanyu Rd, Chongqing 400030, Peoples R China
3.Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
4.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
5.RaySearch China, Shanghai 200120, Peoples R China
6.Chongqing Canc Inst, 181 Hanyu Rd, Chongqing 400030, Peoples R China
7.Wuhan Univ, Sch Phys & Technol, Wuhan 430072, Peoples R China
8.Chongqing Univ Canc Hosp, Dept Radiat Oncol, 181 Hanyu Rd, Chongqing 400030, Peoples R China
9.Chinese Acad Med Sci & Peking Union Med Coll, Shenzhen Hosp, Shenzhen, Peoples R China
10.Chinese Acad Med Sci & Peking Union Med Coll, Natl Canc Ctr, Natl Clin Res Ctr Canc, Canc Hosp, Shenzhen, Peoples R China
推荐引用方式
GB/T 7714
Shang, HJ,Pu, YH,Wang, W,et al. Evaluation of plan quality and robustness of IMPT and helical IMRT for cervical cancer[J]. RADIATION ONCOLOGY,2020,15(1):-.
APA Shang, HJ,Pu, YH,Wang, W,Dai, ZT,&Jin, F.(2020).Evaluation of plan quality and robustness of IMPT and helical IMRT for cervical cancer.RADIATION ONCOLOGY,15(1),-.
MLA Shang, HJ,et al."Evaluation of plan quality and robustness of IMPT and helical IMRT for cervical cancer".RADIATION ONCOLOGY 15.1(2020):-.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。