Methodology development and application of X-ray imaging beamline at SSRF
文献类型:期刊论文
作者 | Xie, HL; Deng, B; Du, GH; Fu, YN; Guo, H; Xue, YL; Peng, GY; Tao, F; Zhang, L; Xiao, TQ |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES |
出版日期 | 2020 |
卷号 | 31期号:10页码:- |
ISSN号 | 1001-8042 |
关键词 | MICROCOMPUTED TOMOGRAPHY IN-VIVO SCAFFOLDS ELECTRODEPOSITION FERTILIZATION EFFICIENCY ADDITIVES INSIGHTS PHASES |
DOI | 10.1007/s41365-020-00805-7 |
文献子类 | 期刊论文 |
英文摘要 | This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline (BL13W1) at Shanghai Synchrotron Radiation Facility in the past 5 years. The photon energy range of the beamline is 8-72.5 keV. Several sets of X-ray imaging detectors with different pixel sizes (0.19-24 mu m) are used to realize X-ray microcomputed tomography (X-ray micro-CT) and X-ray in-line phase-contrast imaging. To satisfy the requirements of user experiments, new X-ray imaging methods and image processing techniques are developed. In vivo dynamic micro-CT experiments with living insects are performed in 0.5 s (sampling rate of 2 Hz, 2 tomograms/s) with a monochromatic beam from a wiggler source and in 40 ms (sampling rate of 25 Hz, 25 tomograms/s) with a white beam from a bending magnet source. A new X-ray imaging method known as move contrast X-ray imaging is proposed, with which blood flow and moving tissues in raw images can be distinguished according to their moving frequencies in the time domain. Furthermore, X-ray speckle-tracking imaging with twice exposures to eliminate the edge enhancement effect is developed. A high-precision quantification method is realized to measure complex three-dimensional blood vessels obtained via X-ray micro-CT. X-ray imaging methods such as three-dimensional X-ray diffraction microscopy, small-angle X-ray scattering CT, and X-ray fluorescence CT are developed, in which the X-ray micro-CT imaging method is combined with other contrast mechanisms such as diffraction, scattering, and fluorescence contrasts respectively. Moreover, an X-ray nano-CT experiment is performed with a 100 nm spatial resolution. Typical user experimental results from the fields of material science, biomedicine, paleontology, physics, chemistry, and environmental science obtained on the beamline are provided. |
语种 | 英语 |
源URL | [http://ir.sinap.ac.cn/handle/331007/33004] |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
作者单位 | 1.Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China 2.Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai Synchrotron Radiat Facil SSRF, Shanghai 201204, Peoples R China |
推荐引用方式 GB/T 7714 | Xie, HL,Deng, B,Du, GH,et al. Methodology development and application of X-ray imaging beamline at SSRF[J]. NUCLEAR SCIENCE AND TECHNIQUES,2020,31(10):-. |
APA | Xie, HL.,Deng, B.,Du, GH.,Fu, YN.,Guo, H.,...&Xiao, TQ.(2020).Methodology development and application of X-ray imaging beamline at SSRF.NUCLEAR SCIENCE AND TECHNIQUES,31(10),-. |
MLA | Xie, HL,et al."Methodology development and application of X-ray imaging beamline at SSRF".NUCLEAR SCIENCE AND TECHNIQUES 31.10(2020):-. |