中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Low Temperature Greatly Enhancing Responses of Aptamer Electrochemical Sensor for Aflatoxin B1 Using Aptamer with Short Stem

文献类型:期刊论文

作者Wang, Chao; Liu, Liying; Zhao, Qiang
刊名ACS SENSORS
出版日期2020-10-23
卷号5期号:10页码:3246-3253
关键词aflatoxin aptamer electrochemical sensor regeneration reagentless detection temperature
ISSN号2379-3694
英文摘要Aflatoxin B1 (AFB1), one of the most toxic mycotoxins, poses great health risks. Rapid and sensitive detection of AFB1 is important for food safety, environment monitoring, and health risk assessment. We report here the development of a simple and reusable electrochemical aptasensor for rapid and sensitive detection of AFB1. Main improvements were achieved through engineering an aptamer containing a short stem-loop structure and enhancing the binding affinity at a lower temperature. The DNA aptamer with a methylene blue (MB) label at one end was immobilized on a gold electrode. Upon AFB1 binding, the aptamer folded into a stem-loop structure and brought MB close to the electrode surface, resulting in increases in electric current. The aptamer having a shorter stem (2-4 bp) underwent a larger conformation change upon target binding. The sensors built with the aptamer containing a 2 bp stem generated much higher signal-on responses to AFB1 at 4 degrees C than at room temperature (25 degrees C). The improvements resulted in a detection limit of 6 pM, enabling the determination of trace AFB1 in a complex sample matrix. This study demonstrates that low temperature greatly enhances the performance of aptamer electrochemical sensors. This aptasensor is simple to construct and readily regenerated by washing with deionized water for reuse. This aptasensor strategy could be applied to the development of an electrochemical aptasensor for other targets.
源URL[http://ir.rcees.ac.cn/handle/311016/44727]  
专题生态环境研究中心_环境化学与生态毒理学国家重点实验室
推荐引用方式
GB/T 7714
Wang, Chao,Liu, Liying,Zhao, Qiang. Low Temperature Greatly Enhancing Responses of Aptamer Electrochemical Sensor for Aflatoxin B1 Using Aptamer with Short Stem[J]. ACS SENSORS,2020,5(10):3246-3253.
APA Wang, Chao,Liu, Liying,&Zhao, Qiang.(2020).Low Temperature Greatly Enhancing Responses of Aptamer Electrochemical Sensor for Aflatoxin B1 Using Aptamer with Short Stem.ACS SENSORS,5(10),3246-3253.
MLA Wang, Chao,et al."Low Temperature Greatly Enhancing Responses of Aptamer Electrochemical Sensor for Aflatoxin B1 Using Aptamer with Short Stem".ACS SENSORS 5.10(2020):3246-3253.

入库方式: OAI收割

来源:生态环境研究中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。