中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Ultrasensitive colorimetric aptasensor for Hg2+ detection using Exo-III assisted target recycling amplification and unmodified AuNPs as indicators

文献类型:期刊论文

作者Memon, Abdul Ghaffar; Xing, Yunpeng; Zhou, Xiaohong; Wang, Ruoyu; Liu, Lanhua; Zeng, Siyu; He, Miao; Ma, Mei
刊名JOURNAL OF HAZARDOUS MATERIALS
出版日期2020-02-15
卷号384页码:1-4
关键词Exonuclease III Mercury (II) ion detection T-Hg2+-T Unmodified gold nanoparticles Enzyme cofactor
ISSN号0304-3894
英文摘要Facile and ultrasensitive detection of Hg2+ in water environment remains challenging. Exonuclease III (Exo-III)-assisted target recycling is one of the most popular amplification strategies. Although the magnesium (II) ions are widely acting as cofactors of Exo-III, we recognized that Mg2+ cofactors would strongly disturb the charge distribution on citrate-stablized gold nanoparticles (in the general sense, unmodified AuNPs) surface, thus generate false positive colorimetric signals. To address this issue, we first put forward the view that the cobalt (II) ions can function as the Exo-III cofactor and successfully construct a novel label-free colorimetric aptasensor for facile and ultrasensitive detection of Hg2+ using Hg2+ -triggered Exo-III-assisted signal amplification and unmodified AuNPs as indicators. A hairpin-looped DNA probe was rationally designed with thymine-rich recognition termini and specifically recognized trace Hg2+ by a stable T-Hg2+-T structure. A blue-to-red color change of AuNPs with the addition of Hg2+ provided the quantitative detection of Hg2+ with a limit of detection of 0.2 nM and a linear working range from 0.5 nM to 5.0 nM. The whole testing time for one assay was approximately 40 min. Real water samples, even containing Hg2+ at 1 nM, could be determined by the aptasensor with recovery rates from 97% to 103%.
源URL[http://ir.rcees.ac.cn/handle/311016/45381]  
专题生态环境研究中心_中国科学院饮用水科学与技术重点实验室
推荐引用方式
GB/T 7714
Memon, Abdul Ghaffar,Xing, Yunpeng,Zhou, Xiaohong,et al. Ultrasensitive colorimetric aptasensor for Hg2+ detection using Exo-III assisted target recycling amplification and unmodified AuNPs as indicators[J]. JOURNAL OF HAZARDOUS MATERIALS,2020,384:1-4.
APA Memon, Abdul Ghaffar.,Xing, Yunpeng.,Zhou, Xiaohong.,Wang, Ruoyu.,Liu, Lanhua.,...&Ma, Mei.(2020).Ultrasensitive colorimetric aptasensor for Hg2+ detection using Exo-III assisted target recycling amplification and unmodified AuNPs as indicators.JOURNAL OF HAZARDOUS MATERIALS,384,1-4.
MLA Memon, Abdul Ghaffar,et al."Ultrasensitive colorimetric aptasensor for Hg2+ detection using Exo-III assisted target recycling amplification and unmodified AuNPs as indicators".JOURNAL OF HAZARDOUS MATERIALS 384(2020):1-4.

入库方式: OAI收割

来源:生态环境研究中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。