Modeling the failures of power-aware data centers by leveraging heat recirculation
文献类型:期刊论文
作者 | Feng, Hao1; Deng, Yuhui1,2; Yu, Liang1 |
刊名 | CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE
![]() |
出版日期 | 2021-04-10 |
卷号 | 33期号:7页码:15 |
关键词 | data center energy efficiency heat recirculation node failure task schedule |
ISSN号 | 1532-0626 |
DOI | 10.1002/cpe.5244 |
英文摘要 | With the explosive growth of data, hundreds of thousands of servers may be contained in a single data center. Hence, node failures are unavoidable and generally negatively effects the performance of the whole data center. Additionally, data centers with a large number of nodes will cause plenty of energy consumption. Many existing task scheduling techniques can effectively reduce the power consumption in data centers by considering heat recirculation. However, the traditional techniques do not take the situation of node failures into account. This paper proposes an airflow-based failure model for data centers by leveraging heat recirculation. In this model, the spatial distribution and time distribution of failures are considered. Furthermore, a genetic algorithm (GA) and a simulated annealing algorithm (SA) are implemented to evaluate the proposed failure model. Because the positions of node failures have a significant impact on the heat recirculation and the energy consumption of data centers, failures with different positions are analyzed and evaluated. The experimental results demonstrate that the energy consumption of data centers can be significantly reduced by using the GA and SA algorithms for task scheduling based on the proposed failure model. |
WOS研究方向 | Computer Science |
语种 | 英语 |
WOS记录号 | WOS:000632049700005 |
出版者 | WILEY |
源URL | [http://119.78.100.204/handle/2XEOYT63/16822] ![]() |
专题 | 中国科学院计算技术研究所期刊论文_英文 |
通讯作者 | Deng, Yuhui |
作者单位 | 1.Jinan Univ, Dept Comp Sci, 601 West Huangpu Ave, Guangzhou 510632, Peoples R China 2.Chinese Acad Sci, Inst Comp Technol, Key Lab Comp Architecture, Beijing, Peoples R China |
推荐引用方式 GB/T 7714 | Feng, Hao,Deng, Yuhui,Yu, Liang. Modeling the failures of power-aware data centers by leveraging heat recirculation[J]. CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE,2021,33(7):15. |
APA | Feng, Hao,Deng, Yuhui,&Yu, Liang.(2021).Modeling the failures of power-aware data centers by leveraging heat recirculation.CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE,33(7),15. |
MLA | Feng, Hao,et al."Modeling the failures of power-aware data centers by leveraging heat recirculation".CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE 33.7(2021):15. |
入库方式: OAI收割
来源:计算技术研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。