中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
CO2 concentration detection system for seed respiration

文献类型:期刊论文

作者L.-Q.Jia; H.-N.Qi; W.-J.Hu; G.-W.Zhao; R.-F.Kan
刊名Guangxue Jingmi Gongcheng/Optics and Precision Engineering
出版日期2019
卷号27期号:6页码:1397-1404
关键词Carbon dioxide,Absorption spectroscopy,Computer control systems,Computer software,Containers,Data acquisition
ISSN号1004924X
DOI10.3788/OPE.20192706.1397
英文摘要To address the problem of low detection accuracy in the traditional method of seed-breathing CO2 concentration measurement, a seed-breathing measurement system based on tunable diode laser absorption spectroscopic technology was proposed to meet the needs of seed-breathing CO2 concentration measurements. First, the system was designed to consist of a seed-breathing container, a distributed feedback laser and control circuit, photoelectric conversion and an amplification circuit, a data acquisition circuit, and upper computer software. The space volume of the seed breathing container was 1.5 L, the laser source was in the 2 004-nm band, and the light path of the multiple reflection cell was 16 m. Then, based on Lambert's law and wavelength modulated absorption spectroscopy, the concentration of CO2 produced during seed respiration could be retrieved in real time using second harmonics. The stable repeatability of the CO2 concentration measurement in seed respiration is 0.033%, the linear fitting degree of CO2 concentration is 0.999 38, and the detection limit of CO2 concentration is 1.710-6. The change curve of 20-g maize seed respiration is obtained by testing waxy maize seeds. The amount of change in waxy maize seed respiration after 12 h is 2 750.510-6, and the respiration rate is 229.210-6/h. Experimental results show that the system can solve the inability for continuous measurement of CO2 concentration in seed respiration and the low precision of concentration detection. 2019, Science Press. All right reserved.
URL标识查看原文
源URL[http://ir.ciomp.ac.cn/handle/181722/63309]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
L.-Q.Jia,H.-N.Qi,W.-J.Hu,et al. CO2 concentration detection system for seed respiration[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2019,27(6):1397-1404.
APA L.-Q.Jia,H.-N.Qi,W.-J.Hu,G.-W.Zhao,&R.-F.Kan.(2019).CO2 concentration detection system for seed respiration.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,27(6),1397-1404.
MLA L.-Q.Jia,et al."CO2 concentration detection system for seed respiration".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 27.6(2019):1397-1404.

入库方式: OAI收割

来源:长春光学精密机械与物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。