On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S
文献类型:期刊论文
作者 | L.Feng; H.Li; B.Inhester; B.Chen; B.L.Ying; L.Lu; W.Q.Gan |
刊名 | Research in Astronomy and Astrophysics
![]() |
出版日期 | 2019 |
卷号 | 19期号:4页码:10 |
关键词 | techniques: polarimeter,solar,Astronomy & Astrophysics |
ISSN号 | 1674-4527 |
DOI | 10.1088/1674-4527/19/4/59 |
英文摘要 | The Advanced Space-based Solar Observatory (ASO-S) mission aims to explore the two most spectacular eruptions on the Sun: solar flares and coronal mass ejections (CMEs), and their magnetism. For the study of CMEs, the payload Lyman-alpha Solar Telescope (LST) has been proposed. It includes a traditional white-light coronagraph and a Lyman-alpha coronagraph which opens a new window to CME observations. Polarization measurements taken by white-light coronagraphs are crucial for deriving fundamental physical parameters of CMEs. To make such measurements, there are two options for a Stokes polarimeter which have been applied by existing white-light coronagraphs for space missions. One uses a single or triple linear polarizer, the other involves both a half-wave plate and a linear polarizer. We find that the former option is subject to less uncertainty in the derived Stokes vector propagating from detector noise. The latter option involves two plates which are prone to internal reflections and may have a reduced transmission factor. Therefore, the former option is adopted as our Stokes polarimeter scheme for LST. Based on the parameters of the intended linear polarizer(s) colorPol provided by CODIXX and the half-wave plate 2-APW-L2-012C by Altechna, it is further shown that the imperfect maximum transmittance of the polarizer significantly increases the variance amplification of Stokes vector by at least about 50% when compared with the ideal case. The relative errors of Stokes vector caused by the imperfection of colorPol polarizer and the uncertainty due to the polarizer assembly in the telescope are estimated to be about 5%. Among the considered parameters, we find that the dominant error comes from the uncertainty in the maximum transmittance of the polarizer. |
URL标识 | 查看原文 |
语种 | 英语 |
源URL | [http://ir.ciomp.ac.cn/handle/181722/63395] ![]() |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | L.Feng,H.Li,B.Inhester,et al. On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S[J]. Research in Astronomy and Astrophysics,2019,19(4):10. |
APA | L.Feng.,H.Li.,B.Inhester.,B.Chen.,B.L.Ying.,...&W.Q.Gan.(2019).On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S.Research in Astronomy and Astrophysics,19(4),10. |
MLA | L.Feng,et al."On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S".Research in Astronomy and Astrophysics 19.4(2019):10. |
入库方式: OAI收割
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。