中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Development of highly sensitive balloon-borne methane measurement system based on cavity ringdown spectroscopy

文献类型:期刊论文

作者F. Yuan,J. Gao,L. Yao,B. Chen,Y.-B. He,M. Hu,Z.-Y. Xu and R.-F. Kan
刊名Guangxue Jingmi Gongcheng/Optics and Precision Engineering
出版日期2020
卷号28期号:9页码:1881-1892
ISSN号1004924X
DOI10.37188/OPE.20202809.1881
英文摘要This paper presents the design for a highly sensitive balloon-borne measurement system based on cavity ringdown spectroscopy (CRDS) in order to analyze the vertical distribution of methane above the Tibetan Plateau. The proposed measurement system uses a digital signal processing (DSP) board to lock the cavity mode, acquire the cavity ringdown signal, scan the laser wavelength, and store data. Calculation of the decay rate, spectral curve fitting, and concentration calculations are all performed via DSP. First, the principle of CRDS and the spectrum calculation algorithm are introduced, including details on the improvement of calculation results by using a fixed Gaussian linewidth for fitting the spectral curve. Second, the cavity ringdown signal and spectral curve of the measurement system were analyzed, yielding a signal-to-noise ratio of approximately 62 dB for the cavity ringdown signal. The measurement system was calibrated in the laboratory by measuring standard gases; the maximum standard deviation of the measured values was 2.210-9, and the adjusted R-square between nominal values and the RMS of the measured values was 0.998 7. Finally, a field test was conducted in Lulang, Tibet. The instrument was carried by a tethered balloon, and methane concentrations at altitudes between 3 340 m and 6 000 m above sea level were successfully measured. Different trace gases can be measured by replacing the super mirrors in the optical cavity and using lasers with appropriate wavelengths, while the measurement system can be refined further to measure the abundances of certain isotopes. 2020, Science Press. All right reserved.
URL标识查看原文
源URL[http://ir.ciomp.ac.cn/handle/181722/64444]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
F. Yuan,J. Gao,L. Yao,B. Chen,Y.-B. He,M. Hu,Z.-Y. Xu and R.-F. Kan. Development of highly sensitive balloon-borne methane measurement system based on cavity ringdown spectroscopy[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2020,28(9):1881-1892.
APA F. Yuan,J. Gao,L. Yao,B. Chen,Y.-B. He,M. Hu,Z.-Y. Xu and R.-F. Kan.(2020).Development of highly sensitive balloon-borne methane measurement system based on cavity ringdown spectroscopy.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,28(9),1881-1892.
MLA F. Yuan,J. Gao,L. Yao,B. Chen,Y.-B. He,M. Hu,Z.-Y. Xu and R.-F. Kan."Development of highly sensitive balloon-borne methane measurement system based on cavity ringdown spectroscopy".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 28.9(2020):1881-1892.

入库方式: OAI收割

来源:长春光学精密机械与物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。