中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands

文献类型:期刊论文

作者A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu
刊名Remote Sensing
出版日期2020
卷号12期号:6页码:21
DOI10.3390/rs12061037
英文摘要GaoFen6 (GF-6), successfully launched on June 2, 2018, is the sixth satellite of the High-Definition Earth observation system (HDEOS). Although GF-6 is the first high-resolution satellite in China to achieve precise agricultural observation, it will be widely used in many other domains, such as land survey, natural resources management, emergency management, ecological environment and so on. The GF-6 was not equipped with an onboard calibration instrument, so on-orbit radiometric calibration is essential. This paper aimed at the on-orbit radiometric calibration of the wide field of view camera (WFV) onboard GF-6 (GF-6/WFV) in multispectral bands. Firstly, the radiometric capability of GF-6/WFV is evaluated compared with the Operational Land Imager (OLI) onboard Landsat-8, Multi Spectral Instrument (MSI) onboard Sentinel-2 and Moderate Resolution Imaging Spectroradiometer (MODIS) onboard Terra, which shows that GF-6/WFV has an obvious attenuation. Consequently, instead of vicarious calibration once a year, more frequent calibration is required to guarantee its radiometric consistency. The cross-calibration method based on the Badain Jaran Desert site using the bi-directional reflectance distribution function (BRDF) model calculated by Landsat-8/OLI and ZY-3/Three-Line Camera (TLC) data is subsequently applied to GF-6/WFV and much higher frequencies of calibration are achieved. Finally, the cross-calibration results are validated using the synchronized ground measurements at Dunhuang test site and the uncertainty of the proposed method is analyzed. The validation shows that the relative difference of cross-calibration is less than 5% and it is satisfied with the requirements of cross-calibration.
URL标识查看原文
语种英语
源URL[http://ir.ciomp.ac.cn/handle/181722/64822]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu. Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands[J]. Remote Sensing,2020,12(6):21.
APA A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu.(2020).Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands.Remote Sensing,12(6),21.
MLA A. X. Yang,B. Zhong,L. F. Hu,S. L. Wu,Z. P. Xu,H. B. Wu,J. J. Wu,X. S. Gong,H. B. Wang and Q. H. Liu."Radiometric Cross-Calibration of the Wide Field View Camera Onboard GaoFen-6 in Multispectral Bands".Remote Sensing 12.6(2020):21.

入库方式: OAI收割

来源:长春光学精密机械与物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。