Measuring the Deflection of the Vertical via Local Reference Point Surveying and Pointing Calibration of a VLBI Telescope: A Case Study at the Urumqi Station
文献类型:期刊论文
作者 | Zhang, Zhibin3,4; Ma, Xiaohui2; Sun, Zhongmiao2; Zhang, Ali1; Yuan, Ye1; Sun, Zhengxiong4 |
刊名 | EARTH AND SPACE SCIENCE |
出版日期 | 2021-10-01 |
卷号 | 8期号:10页码:13 |
关键词 | VLBI deflection of the vertical reference point axis-related errors axis offset |
DOI | 10.1029/2021EA001781 |
通讯作者 | Zhang, Zhibin(zbzhang@shao.ac.cn) |
英文摘要 | According to Newton's law of universal gravitation, the movement of matter and the change in density cause a gravitational variation. Due to the anisotropic distribution of matter, the vertical and the normal directions at a point on the ground are probably inconsistent, which is referred to as the deflection of the vertical (DOV) and is indispensable to astrogeodetic and geophysics research. Two new non-optical methods, including small network transformation and azimuth-axis inclination inversion, are proposed to determine the DOV at a very long baseline interferometry (VLBI) telescope at the Urumqi station. A generalized expression of the pointing calibration model considering axis-related errors is also presented. Therefore, the pointing calibration model and indirect model used for reference point (RP) determination are unified by redefining their coordinate system, angle direction, and axis-related errors. The DOV given by the small network transformation agrees well with the DOVs determined by the real surveying and other different models. Due to the possible asymmetric coverage of calibrating sources in the north-south direction in antenna pointing calibration, the north-south DOV component based on azimuth-axis inclination inversion differs from the surveyed value. However, the west-east DOV component fits well in both direction and magnitude. The proposed methods enable the VLBI telescope to sense the direction of the local plumb line by introducing local leveling. We also establish the connections among VLBI delay observation, RP determination, and telescope pointing calibration, which has a benefit to multi-tech systematic error identification, monitoring, and correction. The research indicates that telescope point calibration can also be taken as a regular technique to monitor systematic error. |
WOS关键词 | RADIO TELESCOPE ; MM-ACCURACY ; NETWORK ; MODEL |
资助项目 | National Natural Science Foundation of China[11873077] |
WOS研究方向 | Astronomy & Astrophysics ; Geology |
语种 | 英语 |
出版者 | AMER GEOPHYSICAL UNION |
WOS记录号 | WOS:000711969700020 |
资助机构 | National Natural Science Foundation of China |
源URL | [http://ir.xao.ac.cn/handle/45760611-7/4321] |
专题 | 新疆天文台_光学天文与技术应用研究室 射电天文研究室_天线技术实验室 射电天文研究室_利用南山26米射电望远镜观测数据的文章 |
通讯作者 | Zhang, Zhibin |
作者单位 | 1.Chinese Acad Sci, Xinjiang Astron Observ, Urumqi, Peoples R China 2.Xian Res Inst Surveying & Mapping, Xian, Peoples R China 3.Univ Chinese Acad Sci, Beijing, Peoples R China 4.Chinese Acad Sci, Shanghai Astron Observ, Shanghai, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Zhibin,Ma, Xiaohui,Sun, Zhongmiao,et al. Measuring the Deflection of the Vertical via Local Reference Point Surveying and Pointing Calibration of a VLBI Telescope: A Case Study at the Urumqi Station[J]. EARTH AND SPACE SCIENCE,2021,8(10):13. |
APA | Zhang, Zhibin,Ma, Xiaohui,Sun, Zhongmiao,Zhang, Ali,Yuan, Ye,&Sun, Zhengxiong.(2021).Measuring the Deflection of the Vertical via Local Reference Point Surveying and Pointing Calibration of a VLBI Telescope: A Case Study at the Urumqi Station.EARTH AND SPACE SCIENCE,8(10),13. |
MLA | Zhang, Zhibin,et al."Measuring the Deflection of the Vertical via Local Reference Point Surveying and Pointing Calibration of a VLBI Telescope: A Case Study at the Urumqi Station".EARTH AND SPACE SCIENCE 8.10(2021):13. |
入库方式: OAI收割
来源:新疆天文台
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。