A design implementation of the Central Process Module for an In-Beam PET in HICTD
文献类型:期刊论文
作者 | Ke, L. Y.1,2; Yan, J. W.1; Chen, J. D.1; Zhang, X. L.1; Wang, C. X.1; Du, C. M.4; Hu, M. C.1,2; Yang, Z. Q.1,2; Qian, Y.1; She, Q. S.1 |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT |
出版日期 | 2021-10-11 |
卷号 | 1013页码:7 |
ISSN号 | 0168-9002 |
关键词 | Data Concentrator In-Beam PET Field programmable gate array (FPGA) Parallel sorters Coincidence events detection |
DOI | 10.1016/j.nima.2021.165572 |
通讯作者 | Kong, J.(kongjie@impcas.ac.cn) |
英文摘要 | To monitor the irradiation dose and position accurately delivered to patient during particle therapy in HeavyIon Cancer Therapy Device (HICTD) in Lanzhou, China, an In-Beam Positron Emission Tomography (PET) has been designed as a detection device to obtain time, energy and position information of gamma ray generated from the annihilation event, which is equipped at the beam line of HICTD. Sixteen detection blocks are adopted to construct a Dual-Head Planar-Type detector array in the In-Beam PET, and each detection block is composed of pixel detection elements. Data Acquisition Unit (DAQU) is employed as the processing module to process and digitize signals from detection blocks. Each DAQU faces a pair of detection blocks, there are eight DAQUs in total in this PET at present. A Central Processor Module (CPM) developed for the detector array is presented in this paper. CPM has two crucial functions: first it is as a hub to connect with all DAQUs through the optical links for data transfer and state control, second it is as a data process engine which collects data from different DAQUs and sorts the events into the chronological order for coincidence event discrimination, and then interfaces both control signals and event data to a host server through PCIe interface for image reconstruction. A novel parallel sorting algorithm has been explored and adopted in CPM, which can effectively sort the valid events detected by detection blocks. The key performance of the CPM has been evaluated in experiments. It can handle the events up to 16 million per second at least, which is capable of sorting and discriminating coincidence events efficiently. |
WOS关键词 | TOF |
资助项目 | National Natural Science Foundation of China[11775285] ; National Natural Science Foundation of China[11975293] ; Youth Innovation Promotion Association, China, CAS, China[2019408] ; Key Deployment Project of Chinese Academy of Sciences[KFZD-SW-222] ; Science and Technology Research Foundation of Gansu Province, China[20JR10RA066] ; Fujian Institute of Innovation, China, CAS[FJCXY18040201] |
WOS研究方向 | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
语种 | 英语 |
出版者 | ELSEVIER |
WOS记录号 | WOS:000685514500015 |
资助机构 | National Natural Science Foundation of China ; Youth Innovation Promotion Association, China, CAS, China ; Key Deployment Project of Chinese Academy of Sciences ; Science and Technology Research Foundation of Gansu Province, China ; Fujian Institute of Innovation, China, CAS |
源URL | [http://119.78.100.186/handle/113462/136593] |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Kong, J. |
作者单位 | 1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China 2.Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing 100049, Peoples R China 3.Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 730000, Peoples R China 4.Chaohu Univ, Sch Elect Engn, Hefei 238000, Peoples R China |
推荐引用方式 GB/T 7714 | Ke, L. Y.,Yan, J. W.,Chen, J. D.,et al. A design implementation of the Central Process Module for an In-Beam PET in HICTD[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2021,1013:7. |
APA | Ke, L. Y..,Yan, J. W..,Chen, J. D..,Zhang, X. L..,Wang, C. X..,...&Kong, J..(2021).A design implementation of the Central Process Module for an In-Beam PET in HICTD.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,1013,7. |
MLA | Ke, L. Y.,et al."A design implementation of the Central Process Module for an In-Beam PET in HICTD".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 1013(2021):7. |
入库方式: OAI收割
来源:近代物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。