Mechanical design of the magnet mirror structure for testing Nb3Sn sextupole coil of 45 GHz ECRIS

文献类型:期刊论文

作者Zhu, L.1,2; Wu, W.1; Yu, S. R.2; Sun, L. T.1; Chen, Y. Y.1; Mei, E. M.1; Ni, D. S.1; Du, Z. Y.1
刊名CRYOGENICS
出版日期2020-12-01
卷号112页码:5
关键词Mirror structure Nb3Sn sextupole coil
ISSN号0011-2275
DOI10.1016/j.cryogenics.2020.103192
通讯作者Zhu, L.(zhuli@impcas.ac.cn)
英文摘要The new Nb3Sn superconducting magnet system for the fourth-generation 45 GHz ECR source is under development at the Institute of Modern Physics (IMP). A mirror structure of the Nb3Sn sextupole testing coil based on an aluminum shell-based structure and bladder & key technology is used for studying the coil's mechanical, thermal and quench performance under realistic conditions. This paper describes the mechanical analyses performed to estimate the sextupole's preload. Based on the three-dimensional finite-element mechanical model, the stress analysis for the process of assembly, cooling down, and charging is carried out. The assembly and strain measurement results of sextupole mirror structure are also introduced in this paper.
WOS关键词HIAF
资助项目NSFC (National Nature Science Foundation of China) research program[11427904] ; National Natural Science Foundation of China[11575266]
WOS研究方向Thermodynamics ; Physics
语种英语
WOS记录号WOS:000605608900006
出版者ELSEVIER SCI LTD
资助机构NSFC (National Nature Science Foundation of China) research program ; National Natural Science Foundation of China
源URL[http://119.78.100.186/handle/113462/138097]  
专题中国科学院近代物理研究所
通讯作者Zhu, L.
作者单位1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
2.Lanzhou Univ Technol, Lanzhou 730050, Peoples R China
推荐引用方式
GB/T 7714
Zhu, L.,Wu, W.,Yu, S. R.,et al. Mechanical design of the magnet mirror structure for testing Nb3Sn sextupole coil of 45 GHz ECRIS[J]. CRYOGENICS,2020,112:5.
APA Zhu, L..,Wu, W..,Yu, S. R..,Sun, L. T..,Chen, Y. Y..,...&Du, Z. Y..(2020).Mechanical design of the magnet mirror structure for testing Nb3Sn sextupole coil of 45 GHz ECRIS.CRYOGENICS,112,5.
MLA Zhu, L.,et al."Mechanical design of the magnet mirror structure for testing Nb3Sn sextupole coil of 45 GHz ECRIS".CRYOGENICS 112(2020):5.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。