中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Loss of thioredoxin reductase function in a mouse stroke model disclosed by a two-photon fluorescent probe

文献类型:期刊论文

作者Zhao, Jintao4; Qu, Yuan1; Gao, Hao1; Zhong, Miao4; Li, Xinming3,4; Zhang, Fang4; Chen, Yaxiong2,4; Gan, Lu2; Hu, Guodong4; Zhang, Hong2
刊名CHEMICAL COMMUNICATIONS
出版日期2020-11-21
卷号56期号:90页码:14075-14078
ISSN号1359-7345
DOI10.1039/d0cc05900e
通讯作者Zhang, Shengxiang(sxzhang@lzu.edu.cn) ; Fang, Jianguo(fangjg@lzu.edu.cn)
英文摘要Thioredoxin reductase (TrxR) enzymes are critical in regulating redox homeostasis in cells. We report the first two-photon fluorescent probe of mammalian TrxR (TP-TRFS). TP-TRFS retains high specificity in recognizing TrxR. More importantly, the two-photon absorbing character of TP-TRFS enables it to be used in vivo. With the aid of TP-TRFS, a remarkable decline of the TrxR function was observed in the brain of a mouse model of stroke for the first time, providing a mechanistic link of TrxR dysfunction with stroke.
WOS关键词CEREBRAL-ISCHEMIA ; OXIDATIVE STRESS ; INHIBITOR ; INJURY
资助项目National Natural Science Foundation of China[21778028] ; National Natural Science Foundation of China[22077055]
WOS研究方向Chemistry
语种英语
出版者ROYAL SOC CHEMISTRY
WOS记录号WOS:000588834100031
资助机构National Natural Science Foundation of China
源URL[http://119.78.100.186/handle/113462/138420]  
专题中国科学院近代物理研究所
通讯作者Zhang, Shengxiang; Fang, Jianguo
作者单位1.Lanzhou Univ, Sch Life Sci, Gansu Key Lab Biomonitoring & Bioremediat Environ, Lanzhou 730000, Peoples R China
2.Chinese Acad Sci, Inst Modern Phys, Dept Heavy Ion Radiat Med, 509 Nanchang Rd, Lanzhou 730000, Peoples R China
3.East China Univ Sci & Technol, Sch Pharm, State Key Lab Bioreactor Engn, Shanghai Key Lab New Drug Design, Shanghai 200237, Peoples R China
4.Lanzhou Univ, State Key Lab Appl Organ Chem, Coll Chem & Chem Engn, Lanzhou 730000, Gansu, Peoples R China
推荐引用方式
GB/T 7714
Zhao, Jintao,Qu, Yuan,Gao, Hao,et al. Loss of thioredoxin reductase function in a mouse stroke model disclosed by a two-photon fluorescent probe[J]. CHEMICAL COMMUNICATIONS,2020,56(90):14075-14078.
APA Zhao, Jintao.,Qu, Yuan.,Gao, Hao.,Zhong, Miao.,Li, Xinming.,...&Fang, Jianguo.(2020).Loss of thioredoxin reductase function in a mouse stroke model disclosed by a two-photon fluorescent probe.CHEMICAL COMMUNICATIONS,56(90),14075-14078.
MLA Zhao, Jintao,et al."Loss of thioredoxin reductase function in a mouse stroke model disclosed by a two-photon fluorescent probe".CHEMICAL COMMUNICATIONS 56.90(2020):14075-14078.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。