中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
X-Mode Frequency Modulated Density Profile Reflectometer on EAST Tokamak

文献类型:期刊论文

作者Zhang Chongyang; Liu Ahdi; Li Hong; Li Bin; Zhou Chu; Zhang Xiaohui; Hu Jianqiang; Xie Jinlin; Liu Wandong; Yu Changxuan
刊名PLASMA SCIENCE & TECHNOLOGY
出版日期2013
卷号15期号:9
关键词MICROWAVE REFLECTOMETRY DIII-D ASDEX UPGRADE PLASMAS reflectometer electron density H-mode CDM
ISSN号1009-0630
其他题名X-Mode Frequency Modulated Density Profile Reflectometer on EAST Tokamak
英文摘要An extraordinary-mode (X-mode) frequency-modulated continuous-wave (FMCW) profile reflectometer has been built on EAST. In the reflectometer, continuous waves with frequency sweeping from 12.5 GHz to 18 GHz were generated through a Hyperabrupt Tuned-varactor Oscillator (HTO) source and a four times active multiplier was used to increase the frequency to V-band (50 GHz to 72 GHz). The polarization of horn lens antenna is perpendicular to the magnetic field line at the edge plasmas. According to the V-band frequency range and polarization, the system cover density range from 0.5 x 10(19)m(-3) to 3.0 x 10(19)m(-3) (when toroidal magnetic field is 1.8 T), with time resolution of 12.5 50 his. The density profile could be calculated by assuming the edge profile through an empirical equation. The maximum spatial error deduced by the method is about 4 cm. This reflectometer has been successfully applied in 2010 autumn EAST campaign, the temporal evolution of density profiles was acquired during the low confinement mode to high confinement mode transition. The density pedestal of EAST Tokamak was observed and the top value and gradient of the density pedestal were estimated.
资助项目[National Natural Science Foundation of China] ; [ITER Domestic Program of China] ; [Fundamental Research Funds for the Central Universities]
语种英语
CSCD记录号CSCD:4925075
源URL[http://119.78.100.186/handle/113462/138910]  
专题中国科学院近代物理研究所
作者单位中国科学院近代物理研究所
推荐引用方式
GB/T 7714
Zhang Chongyang,Liu Ahdi,Li Hong,et al. X-Mode Frequency Modulated Density Profile Reflectometer on EAST Tokamak[J]. PLASMA SCIENCE & TECHNOLOGY,2013,15(9).
APA Zhang Chongyang.,Liu Ahdi.,Li Hong.,Li Bin.,Zhou Chu.,...&Yu Changxuan.(2013).X-Mode Frequency Modulated Density Profile Reflectometer on EAST Tokamak.PLASMA SCIENCE & TECHNOLOGY,15(9).
MLA Zhang Chongyang,et al."X-Mode Frequency Modulated Density Profile Reflectometer on EAST Tokamak".PLASMA SCIENCE & TECHNOLOGY 15.9(2013).

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。