中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Evaluation of energy correction algorithm for signals of PET in heavy-ion cancer therapy device

文献类型:期刊论文

作者Niu, Xiaoyang1,2; Yan, Junwei1,2; Wang, Xiaohui3; Yang, Haibo1; Ke, Lingyun1,2; Chen, Jinda1; Du, Chengming1; Zhang, Xiuling1; Zhao, Chengxin1; Kong, Jie1
刊名NUCLEAR ENGINEERING AND TECHNOLOGY
出版日期2020
卷号52期号:1页码:101-108
ISSN号1738-5733
关键词Positron emission tomography Correction algorithm Energy extraction
DOI10.1016/j.net.2019.07.008
通讯作者Kong, Jie(kongjie@impcas.ac.cn)
英文摘要In order to solve the contradiction between requirements of high sampling rate for acquiring accurate energy information of pulses and large amount of data to be processed timely, the method with an algorithm to correct errors caused by reducing the sampling rate is normally used in front-end read-out system, which is conductive to extract accurate energy information from digitized waveform of pulse. The functions and effects of algorithms, which mainly include polynomial fitting with different fitting times, double exponential function fitting under different sampling modes, and integral area algorithm, are analyzed and evaluated, and some meaningful results is presented in this paper. The algorithm described in the paper has been used preliminarily in a prototype system of Positron Emission Tomography (PET) for heavy-ion cancer therapy facility. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
WOS关键词FRONT-END ELECTRONICS
资助项目National Natural Science Foundation of China[11775285] ; National Natural Science Foundation of China[11605265] ; National Key Research and Development Program of China[2016YFB0701001] ; Youth Innovation Promotion Association, CAS[2016362] ; Youth Innovation Promotion Association, CAS[2019408] ; Function development project, CAS[2020g101] ; Fujian Institute of Innovation, CAS[FJCXY18040201]
WOS研究方向Nuclear Science & Technology
语种英语
出版者KOREAN NUCLEAR SOC
WOS记录号WOS:000506878400011
资助机构National Natural Science Foundation of China ; National Key Research and Development Program of China ; Youth Innovation Promotion Association, CAS ; Function development project, CAS ; Fujian Institute of Innovation, CAS
源URL[http://119.78.100.186/handle/113462/141461]  
专题中国科学院近代物理研究所
通讯作者Kong, Jie
作者单位1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
2.Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing 100049, Peoples R China
3.Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
推荐引用方式
GB/T 7714
Niu, Xiaoyang,Yan, Junwei,Wang, Xiaohui,et al. Evaluation of energy correction algorithm for signals of PET in heavy-ion cancer therapy device[J]. NUCLEAR ENGINEERING AND TECHNOLOGY,2020,52(1):101-108.
APA Niu, Xiaoyang.,Yan, Junwei.,Wang, Xiaohui.,Yang, Haibo.,Ke, Lingyun.,...&Su, Hong.(2020).Evaluation of energy correction algorithm for signals of PET in heavy-ion cancer therapy device.NUCLEAR ENGINEERING AND TECHNOLOGY,52(1),101-108.
MLA Niu, Xiaoyang,et al."Evaluation of energy correction algorithm for signals of PET in heavy-ion cancer therapy device".NUCLEAR ENGINEERING AND TECHNOLOGY 52.1(2020):101-108.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。