Precise calibration of cavity forward and reflected signals using low-level radio-frequency system
文献类型:期刊论文
作者 | Ma, Jin-Ying1; Qiu, Feng1,2; Shi, Long-Bo1; Zhu, Zheng-Long1; Jiang, Tian-Cai1; Xue, Zong-Heng1; Jin, Ke-An1; Chen, Qi1; Xu, Cheng-Ye1; Ding, Xing-Hao2 |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES |
出版日期 | 2022 |
卷号 | 33期号:1页码:9 |
ISSN号 | 1001-8042 |
关键词 | Forward and reflected signals Measurement Calibration |
DOI | 10.1007/s41365-022-00985-4 |
通讯作者 | Qiu, Feng(qiufeng@impcas.ac.cn) |
英文摘要 | Precise measurements of the cavity forward (V-f) and reflected signals (V-r) are essential for characterizing other key parameters such as the cavity detuning and for ward power. In practice, it is challenging to measure V-f and V-r precisely because of cross talk between the forward and reflected channels (e.g., coupling between the cavity reflected and forward signals in a directional coupler with limited directivity). For DESY, a method based on the cavity differential equation was proposed to precisely calibrate the actual V-f and V-r. In this study, we verified the validity and practicability of this approach for the Chinese ADS front-end demo superconducting linac (CAFe) facility at the Institute of Modern Physics and a compact energy recovery linac (cERL) test machine at KEK. At the CAFe facility, we successfully calibrated the actual V-f signal using this method. The result demonstrated that the directivity of directional couplers might seriously affect the accuracy of V-f measurement. At the cERL facility, we calibrated the Lorentz force detuning (LFD) using the actual V-f. Our study confirmed that the precise calibration of V-f significantly improves the accuracy of the cavity LFD measurement. |
WOS关键词 | DESIGN |
资助项目 | project of ``studies of intelligent LLRF control algorithms for superconducting RF cavities[E129851YR0] |
WOS研究方向 | Nuclear Science & Technology ; Physics |
语种 | 英语 |
出版者 | SPRINGER SINGAPORE PTE LTD |
WOS记录号 | WOS:000743542500002 |
资助机构 | project of ``studies of intelligent LLRF control algorithms for superconducting RF cavities |
源URL | [http://119.78.100.186/handle/113462/142316] |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Qiu, Feng |
作者单位 | 1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China 2.Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Ma, Jin-Ying,Qiu, Feng,Shi, Long-Bo,et al. Precise calibration of cavity forward and reflected signals using low-level radio-frequency system[J]. NUCLEAR SCIENCE AND TECHNIQUES,2022,33(1):9. |
APA | Ma, Jin-Ying.,Qiu, Feng.,Shi, Long-Bo.,Zhu, Zheng-Long.,Jiang, Tian-Cai.,...&He, Yuan.(2022).Precise calibration of cavity forward and reflected signals using low-level radio-frequency system.NUCLEAR SCIENCE AND TECHNIQUES,33(1),9. |
MLA | Ma, Jin-Ying,et al."Precise calibration of cavity forward and reflected signals using low-level radio-frequency system".NUCLEAR SCIENCE AND TECHNIQUES 33.1(2022):9. |
入库方式: OAI收割
来源:近代物理研究所