Pencil-beam scanning catheter for intracoronary optical coherence tomography
文献类型:期刊论文
作者 | Kang, Jiqiang6; Zhu, Rui3,4,5; Sun, Yunxu6; Li, Jianan3,4; Wong, Kenneth K. Y.1,2 |
刊名 | OPTO-ELECTRONIC ADVANCES
![]() |
出版日期 | 2022 |
卷号 | 5期号:3 |
关键词 | optical coherence tomography endoscopic imaging intravascular imaging fiber optics imaging |
ISSN号 | 2096-4579 |
DOI | 10.29026/oea.2022.200050 |
产权排序 | 4 |
英文摘要 | Current gradient-index (GRIN) lens based proximal-driven intracoronary optical coherence tomography (ICOCT) probes consist of a spacer and a GRIN lens with large gradient constant. This design provides great flexibility to control beam profiles, but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication. Besides, although GRIN lens with large gradient constant can provide tight focus spot, it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue. In this paper, a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens. This design simplifies the fabrication process and is suitable for mass production. The output beam of the catheter is a narrow nearly collimated light beam, referred to as pencil beam here. The full width at half maximum beam size varies from 35.1 mu m to 75.3 mu m in air over 3-mm range. Probe design principles are elaborated with probe/catheter fabrication and performance test. The in vivo imaging of the catheter was verified by a clinical ICOCT system. Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems. |
语种 | 英语 |
WOS记录号 | WOS:000778790100002 |
出版者 | CAS, INST OPTICS & ELECTRONICS, ED OFF OPTO-ELECTRONIC JOURNALS |
源URL | [http://ir.opt.ac.cn/handle/181661/95817] ![]() |
专题 | 西安光学精密机械研究所_瞬态光学技术国家重点实验室 |
通讯作者 | Sun, Yunxu; Wong, Kenneth K. Y. |
作者单位 | 1.Adv Biomed Instrumentat Ctr, Shatin, Hong Kong Sci Pk, Hong Kong, Peoples R China 2.Univ Hong Kong, Dept Elect & Elect Engn, Pokfulam Rd, Hong Kong, Peoples R China 3.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transient Opt & Photon, Xian 710119, Peoples R China 4.Shenzhen Vivolight Med Device & Technol Co Ltd, Shenzhen 518055, Peoples R China 5.Tsinghua Univ, Int Grad Sch Shenzhen, Shenzhen 518055, Peoples R China 6.Harbin Inst Technol Shenzhen, Sch Elect & Informat Engn, Shenzhen 518055, Peoples R China |
推荐引用方式 GB/T 7714 | Kang, Jiqiang,Zhu, Rui,Sun, Yunxu,et al. Pencil-beam scanning catheter for intracoronary optical coherence tomography[J]. OPTO-ELECTRONIC ADVANCES,2022,5(3). |
APA | Kang, Jiqiang,Zhu, Rui,Sun, Yunxu,Li, Jianan,&Wong, Kenneth K. Y..(2022).Pencil-beam scanning catheter for intracoronary optical coherence tomography.OPTO-ELECTRONIC ADVANCES,5(3). |
MLA | Kang, Jiqiang,et al."Pencil-beam scanning catheter for intracoronary optical coherence tomography".OPTO-ELECTRONIC ADVANCES 5.3(2022). |
入库方式: OAI收割
来源:西安光学精密机械研究所
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。