Rapid Simultaneous Screening and Detection of 12 Anticoagulant Rodenticides in Food by Ultra-performance Liquid Chromatography-Triple Quadrupole_Linear Ion Trap Tandem Mass Spectrometry
文献类型:期刊论文
作者 | Cao, Xiaoli; Yang, Xiaoqian; Liu, Zhong; Jiao, Haitao; Liu, Suhua; Liu, Lanzheng; Meng, Qingfen![]() |
刊名 | FOOD ANALYTICAL METHODS
![]() |
出版日期 | 2017-11 |
卷号 | 10期号:11页码:3538-3547 |
ISSN号 | 1936-9751 |
DOI | 10.1007/s12161-017-0922-2 |
英文摘要 | A rapid analytical method for the simultaneous screening and detection of 12 anticoagulant rodenticides in food samples was established based on modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method using an ultra-performance liquid chromatography-triple quadrupole/linear ion trap tandem mass spectrometry (UPLC-QTrap-MS/MS). Food samples were extracted and purified with modified QuEChERS method. The 12 anticoagulant rodenticides (warfarin, brodifacoum, difethialone, coumachlor, coumatetralyl, bromadiolone, chlorophacinone, difenacoum, diphacinone, pindone, valone, and flocoumafen) and the internal standard (warfarin-D-5) were separated within 6 min using an ACQUITY UPLC BEH-C18 column (1.7 mu m, 2.1 mm x 50 mm) and gradient elution with the mobile phase consisting of 5 mM ammonium acetate formate buffer and acetonitrile. The multiple reaction monitoring-information dependent acquisition-enhanced product ion (MRM-IDA-EPI) scanning was employed for detection. The calibration curves were linear (R (2) > 0.99) for all the compounds. The mean recoveries for the 12 analytes at three spiked levels (1x LOQ, 5x LOQ, and 10x LOQ) were in the range of 79.5-113.2% with RSDs of 1.8-13.2%.The limits of detection (LOD) for the 12 rodenticides ranged from 0.01 (warfarin) to 0.05 mu g/kg (diphacinone). The limit of quantification (LOQ) for the 12 rodenticides was between 0.02 (warfarin) and 0.10 mu g/kg (diphacinone). The developed method was more straightforward, less time and labor intensive, and more sensitive, selective, and accurate for screening multiple anticoagulant rodenticides, and it was successfully used in several poisoning cases. |
源URL | [http://ir.isl.ac.cn/handle/363002/34566] ![]() |
专题 | 青海盐湖研究所_盐湖资源综合利用工程技术中心 |
推荐引用方式 GB/T 7714 | Cao, Xiaoli,Yang, Xiaoqian,Liu, Zhong,et al. Rapid Simultaneous Screening and Detection of 12 Anticoagulant Rodenticides in Food by Ultra-performance Liquid Chromatography-Triple Quadrupole_Linear Ion Trap Tandem Mass Spectrometry[J]. FOOD ANALYTICAL METHODS,2017,10(11):3538-3547. |
APA | Cao, Xiaoli.,Yang, Xiaoqian.,Liu, Zhong.,Jiao, Haitao.,Liu, Suhua.,...&Meng, Qingfen.(2017).Rapid Simultaneous Screening and Detection of 12 Anticoagulant Rodenticides in Food by Ultra-performance Liquid Chromatography-Triple Quadrupole_Linear Ion Trap Tandem Mass Spectrometry.FOOD ANALYTICAL METHODS,10(11),3538-3547. |
MLA | Cao, Xiaoli,et al."Rapid Simultaneous Screening and Detection of 12 Anticoagulant Rodenticides in Food by Ultra-performance Liquid Chromatography-Triple Quadrupole_Linear Ion Trap Tandem Mass Spectrometry".FOOD ANALYTICAL METHODS 10.11(2017):3538-3547. |
入库方式: OAI收割
来源:青海盐湖研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。