Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement

文献类型:期刊论文

作者Zhang, Xuanhao2; Sun, Lijuan1; Wang, Bo2; Pan, Bing2; Sun LJ(孙立娟)
刊名MEASUREMENT
出版日期2022-05-15
卷号194页码:12
关键词Digital volume correlation Number of projections X-ray computed tomography FDK algorithm
ISSN号0263-2241
DOI10.1016/j.measurement.2022.111061
通讯作者Pan, Bing(panb@buaa.edu.cn)
英文摘要Digital volume correlation (DVC) quantifies internal 3D displacement and strain fields by correlating the volume images of a tested object acquired at different states. When using X-ray CT-based DVC, the number of projections is a key parameter that affects the acquisition time and quality of reconstructed volumetric images, and therefore the precision and temporal resolutions of DVC measurement. More projections result in high-quality volume images for DVC calculation but longer acquisition time and pronounced thermal drifts of the X-ray source. Few projections lead to quicker acquisition and fewer thermal drifts, but may degrade image quality and thus induce larger DVC measurement errors. Selecting an appropriate number of projections during CT imaging is therefore of practical significance for DVC measurement. To solve this dilemma, the effect of the number of projections on DVC measurements with X-ray CT is experimentally investigated in this work. First, numerically simulated speckle volume images with different numbers of projections were reconstructed by using FDK (Feldkamp) al-gorithm, and the influence of the number of projections on DVC measurement was analyzed. Then, real rescan and compression experiments performed on a copper foam sample were carried out to further study the effect of projection number on DVC measurements. Both simulation and real experiments show that more projections result in longer imaging time but higher quality volume image and DVC measurement. DVC measurement errors decrease with the increase of projections at different decline rates. Therefore, an appropriate number of pro-jections can be specified based on the results according to the requirements of DVC measurement precision and temporal resolution. For the specific X-ray CT device used in this real compression experiment, 36 ~ 60 pro-jections are suggested to balance measurement precision and temporal resolution, and more than 720 projections are necessary for pursuing higher accuracy.
WOS关键词TOMOGRAPHY ; STRAIN
资助项目National Natural Science Foundation of China[11925202] ; National Natural Science Foundation of China[11872009]
WOS研究方向Engineering ; Instruments & Instrumentation
语种英语
WOS记录号WOS:000793176700002
资助机构National Natural Science Foundation of China
源URL[http://dspace.imech.ac.cn/handle/311007/89351]  
专题力学研究所_非线性力学国家重点实验室
通讯作者Pan, Bing
作者单位1.Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China
2.Beihang Univ, Inst Solid Mech, Beijing 100191, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Xuanhao,Sun, Lijuan,Wang, Bo,et al. Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement[J]. MEASUREMENT,2022,194:12.
APA Zhang, Xuanhao,Sun, Lijuan,Wang, Bo,Pan, Bing,&孙立娟.(2022).Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement.MEASUREMENT,194,12.
MLA Zhang, Xuanhao,et al."Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement".MEASUREMENT 194(2022):12.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。