Feasibility of applying the lower cut-off frequency for the density radial coverage extension in EAST reflectometry measurement
文献类型:期刊论文
作者 | HUANG,Jia1,4; HAN,Xiang4![]() ![]() ![]() ![]() |
刊名 | Plasma Science and Technology
![]() |
出版日期 | 2022-05-01 |
卷号 | 24 |
关键词 | X-mode reflectometry density profile EAST lower cut-off frequency |
ISSN号 | 1009-0630 |
DOI | 10.1088/2058-6272/ac52e9 |
通讯作者 | HUANG,Jia() |
英文摘要 | Abstract The extraordinary mode (X-mode) lower cut-off frequency is proposed for use in the reflectometry diagnostic on ITER for the electron density profile measurement, which is a trade-off between extreme plasma parameters and the accessible probing frequency. In contemporary experiments, the lower cut-off frequency can be identified at the probing frequency below the electron cyclotron frequency (f ce) under certain plasma conditions. We provide here, for the first time, the experimental validation of the use of the lower cut-off frequency for the density profiles via the reflectometry measurement on EAST. The corresponding group delay of the lower cut-off frequency evolves continuously with the upper one, revealing a reasonable radial coverage extension of reflectometry measurement toward the plasma core. It is concluded that the lower cut-off frequency can be used as a supplement to the upper one in the density profile inversion process, which is of particular interest in the high magnetic field and/or density discharge to extend the radial coverage of reflectometry measurement. |
语种 | 英语 |
WOS记录号 | IOP:PST_24_5_050001 |
出版者 | IOP Publishing |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/129639] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | HUANG,Jia |
作者单位 | 1.University of Science and Technology of China, Hefei 230026, People's Republic of China 2.Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, People's Republic of China 3.Advanced Energy Research Center, Shenzhen University, Shenzhen 518060, People's Republic of China 4.Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, People's Republic of China |
推荐引用方式 GB/T 7714 | HUANG,Jia,HAN,Xiang,YE,Kaixuan,et al. Feasibility of applying the lower cut-off frequency for the density radial coverage extension in EAST reflectometry measurement[J]. Plasma Science and Technology,2022,24. |
APA | HUANG,Jia.,HAN,Xiang.,YE,Kaixuan.,ZHANG,Tao.,WEN,Fei.,...&,.(2022).Feasibility of applying the lower cut-off frequency for the density radial coverage extension in EAST reflectometry measurement.Plasma Science and Technology,24. |
MLA | HUANG,Jia,et al."Feasibility of applying the lower cut-off frequency for the density radial coverage extension in EAST reflectometry measurement".Plasma Science and Technology 24(2022). |
入库方式: OAI收割
来源:合肥物质科学研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。