Study on Laser Parameter Measurement System Based on Cone-Arranged Fibers and CCD Camera
文献类型:期刊论文
作者 | Luo, Jie1,2,3; Qin, Laian1,3; Hou, Zaihong1,3; Zhang, Silong1,3; Zhu, Wenyue1,2,3; Guan, Wenlu1,2,3 |
刊名 | SENSORS |
出版日期 | 2022-10-01 |
卷号 | 22 |
关键词 | laser parameter array fibers CCD camera integrated optics PIB |
DOI | 10.3390/s22207892 |
通讯作者 | Qin, Laian(laqin@aiofm.ac.cn) |
英文摘要 | This paper proposes a new laser parameter measuring method based on cone-arranged fibers to further improve the measurable spot size, allowable incident angle range, and spatial sampling resolution. This method takes a conical array composed of flexible fibers to sample and shrink the cross-section spot of the laser beam, facilitating low-distortion shooting with a charge-coupled diode (CCD) camera, and adopts homogenized processing and algorithm analysis to correct the spot. This method is experimentally proven to achieve high-accuracy measurements with a decimeter-level spot-receiving surface, millimeter-level resolution, and high tolerance in order to incite skew angle. Comparing the measured spot under normal incidence with the real one, the root mean square error (RMSE) of their power in the bucket (PIB) curves is less than 1%. When the incident angle change is between -8 degrees and 8 degrees, the RMSE is less than 2% and the measurement error of total power is less than 5% based on the premise that the fiber's numerical aperture (NA) is 0.22. The possibility of further optimizing the measurement method by changing the fiber parameters and array design is also reported. |
WOS关键词 | BEAM QUALITY ; DELIVERY ; LOSSES |
WOS研究方向 | Chemistry ; Engineering ; Instruments & Instrumentation |
语种 | 英语 |
出版者 | MDPI |
WOS记录号 | WOS:000873641200001 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/130017] |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Qin, Laian |
作者单位 | 1.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei Inst Phys Sci, Key Lab Atmospher Opt, Hefei 230031, Anhui, Peoples R China 2.Univ Sci & Technol China, Sch Environm Sci & Optoelect Technol, Hefei 230026, Peoples R China 3.State Key Lab Pulsed Power Laser Technol, Hefei 230037, Peoples R China |
推荐引用方式 GB/T 7714 | Luo, Jie,Qin, Laian,Hou, Zaihong,et al. Study on Laser Parameter Measurement System Based on Cone-Arranged Fibers and CCD Camera[J]. SENSORS,2022,22. |
APA | Luo, Jie,Qin, Laian,Hou, Zaihong,Zhang, Silong,Zhu, Wenyue,&Guan, Wenlu.(2022).Study on Laser Parameter Measurement System Based on Cone-Arranged Fibers and CCD Camera.SENSORS,22. |
MLA | Luo, Jie,et al."Study on Laser Parameter Measurement System Based on Cone-Arranged Fibers and CCD Camera".SENSORS 22(2022). |