Upgrade of the magnetic diagnostic system for restart of HT-6M operation
文献类型:期刊论文
作者 | Chen, Li-Xing1,2; Shen, Biao1; Chen, Da-Long1; Luo, Zheng-Ping1; Zhang, Zu-Chao1; Chen, Ying1; Wang, Yong1; Qian, Jin-Ping1 |
刊名 | CHINESE PHYSICS B |
出版日期 | 2022-11-01 |
卷号 | 31 |
ISSN号 | 1674-1056 |
关键词 | HT-6M null field magnetic measurement high frequency calibration |
DOI | 10.1088/1674-1056/ac7f93 |
通讯作者 | Chen, Da-Long(cdalong@ipp.ac.cn) ; Luo, Zheng-Ping(zhpluo@ipp.ac.cn) |
英文摘要 | The HT-6M tokamak at the Thailand Institute of Nuclear Technology has been restarted. In order to ensure the smooth breakdown of plasma and obtain plasma discharge parameters, optimization of the poloidal field coils and upgrade of the magnetic diagnostics are described in this article. A perfect null field (stray field in the main chamber < 10 G) is obtained using an ohmic heating field. To obtain important information about the plasma, an external magnetic diagnostics system is designed and calibrated, including a Rogowski coil (measuring plasma current), a magnetic probe (measuring external field), diamagnetic loops (measuring beta (p)) and so on. In order to realize high-frequency signal measurement and transmission, a series of frequency responses with the magnetic probe and transmission line are tested. Later, to verify the null field, a fitting code is developed to reconstruct the stray field in the vacuum chamber based on magnetic probe measurements and flux loops. The results show that the error is within 1.5%. This indicates the accuracy of the magnetic measurement system and ensures the preparation for the breakdown of plasma. |
WOS关键词 | RECONSTRUCTION ; EQUILIBRIUM |
资助项目 | National MCF Energy Research and Development Program of China ; National Natural Science Foundation of China ; Comprehensive Research Facility for Fusion Technology Program of China ; [2018YFE0302100] ; [2018YFE0301105] ; [11875291] ; [2018-000052-73-01-001228] |
WOS研究方向 | Physics |
语种 | 英语 |
出版者 | IOP Publishing Ltd |
WOS记录号 | WOS:000889806700001 |
资助机构 | National MCF Energy Research and Development Program of China ; National Natural Science Foundation of China ; Comprehensive Research Facility for Fusion Technology Program of China |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/131640] |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Chen, Da-Long; Luo, Zheng-Ping |
作者单位 | 1.Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230026, Peoples R China 2.Univ Sci & Technol China, Hefei 230026, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Li-Xing,Shen, Biao,Chen, Da-Long,et al. Upgrade of the magnetic diagnostic system for restart of HT-6M operation[J]. CHINESE PHYSICS B,2022,31. |
APA | Chen, Li-Xing.,Shen, Biao.,Chen, Da-Long.,Luo, Zheng-Ping.,Zhang, Zu-Chao.,...&Qian, Jin-Ping.(2022).Upgrade of the magnetic diagnostic system for restart of HT-6M operation.CHINESE PHYSICS B,31. |
MLA | Chen, Li-Xing,et al."Upgrade of the magnetic diagnostic system for restart of HT-6M operation".CHINESE PHYSICS B 31(2022). |
入库方式: OAI收割
来源:合肥物质科学研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。