中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Detection and analysis of phage M13KO7 using biosensor based on imaging ellipsometry

文献类型:期刊论文

作者Qi C; Zhang YX; Lei WJ; Jin G(靳刚)
刊名THIN SOLID FILMS
出版日期2022-12-01
卷号763页码:8
关键词Optical biosensor Imaging ellipsometry Microfluidic system Phage M13KO7 Detection
ISSN号0040-6090
DOI10.1016/j.tsf.2022.139563
通讯作者Qi, Cai(qicaisucceed@henu.edu.cn)
英文摘要Antibody GP8 (anti-GP8) was used as a ligand to detect phage M13KO7 using a biosensor based on imaging ellipsometry (IE) without oriented ligand immobilization. When the phage M13KO7 in a sample interacted with the antibody in a microarray, a complex formed upon their affinity, and the layer covering the surface cell of the interaction became thicker. The variation in layer thickness was represented by gray-scale (or brightness) variation of the IE image. Direct and oriented immobilization of the antibody were analyzed to identify the best binding locations to capture the phage. In direct immobilization, the phage could be captured by anti-GP8 and not antibody GP3 (anti-GP3), which was attributed to different copy numbers of the coat proteins on the body of the phage specific to the two antibodies. This indicated that different binding locations could produce different detection efficiency. In oriented immobilization, the phage could be captured by the protein G-Fc-anti-GP3 model, with a low detection efficiency. In contrast, the avidin-biotin-based oriented immobilization could capture the phage with a high detection efficiency. Specifically, it could expose more Fab domains of anti-GP3 labeled with biotin; one avidin had four biotin-binding sites. To confirm detection and analyze binding location, the phage M13KO7 was imaged by transmission electron microscopy and atomic force microscopy. Our results suggest that binding location plays a significant role in the detection of big targets and contributes to enhancing biosensor detection sensitivity.
分类号Q3
WOS关键词PROTEIN-A ; FORCE ; ANTIBODY ; SURFACE ; IMMOBILIZATION ; VISUALIZATION ; LIGAND
资助项目Fund for Yellow River scholars of Henan University ; Guiyang Science and Technology Planning Project[[2021] S105] ; Guiyang Talent Innovation and Entrepreneur Fundation of China ; Guizhou Province ; [[2020] 4Y188]
WOS研究方向Materials Science ; Physics
语种英语
WOS记录号WOS:000886685800002
资助机构Fund for Yellow River scholars of Henan University ; Guiyang Science and Technology Planning Project ; Guiyang Talent Innovation and Entrepreneur Fundation of China ; Guizhou Province
其他责任者Qi, Cai
源URL[http://dspace.imech.ac.cn/handle/311007/91053]  
专题力学研究所_国家微重力实验室
推荐引用方式
GB/T 7714
Qi C,Zhang YX,Lei WJ,et al. Detection and analysis of phage M13KO7 using biosensor based on imaging ellipsometry[J]. THIN SOLID FILMS,2022,763:8.
APA Qi C,Zhang YX,Lei WJ,&靳刚.(2022).Detection and analysis of phage M13KO7 using biosensor based on imaging ellipsometry.THIN SOLID FILMS,763,8.
MLA Qi C,et al."Detection and analysis of phage M13KO7 using biosensor based on imaging ellipsometry".THIN SOLID FILMS 763(2022):8.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。