中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Time and charge calibration of the LHAASO electromagnetic particle detectors

文献类型:会议论文

作者Pang, Binyu8; Lv, Hongkui1; Sheng, Xiangdong1; Liu, Jia1; Zhang, Xiaopeng1; He, Yu8; Cao, Zhen1,2,3; Aharonian, F.4,5; An, Q.6,7; Axikegu8
出版日期2022-03-18
会议日期2021-07-12
会议地点Virtual, Berlin, Germany
卷号395
DOI10.22323/1.395.0740
英文摘要

The one square kilometer array (KM2A), a sub-array of Large High Altitude Air Shower Observatory (LHAASO) experiment, consists of 5195 electromagnetic particle detectors (EDs) and 1188 muon detectors (MDs), has been built over three-quarters scale. Its main scientific goal is to search gamma-ray sources at energies above 100 TeV. Offline calibration method has been used to calibrate thousands of EDs to guarantee the key performances of the array such as angular resolution and pointing accuracy within 0.1° during long-term operation. The experimental results of the 3/4 array show that this method can be used to determine the detector time offset with an accuracy of 0.5 ns and the particle number density with an accuracy of a few percent. Furthermore, we monitor the calibration parameters during the array operation and update the calibration results regularly to ensure the data quality of the detector. © 2022 Sissa Medialab Srl. All rights reserved.

产权排序第29完成单位
资助机构N/A
会议录Proceedings of Science
会议录出版者Sissa Medialab Srl
文献子类Conference article (CA)
学科主题天文学 ; 天体物理学 ; 高能天体物理学 ; 核科学技术
语种英语
URL标识查看原文
资助项目N/A
源URL[http://ir.ynao.ac.cn/handle/114a53/25702]  
专题星系类星体研究组
作者单位1.Key Laboratory of Particle Astrophyics & Experimental Physics Division & Computing Center, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, China;
2.University of Chinese Academy of Sciences, Beijing, 100049, China;
3.TIANFU Cosmic Ray Research Center, Sichuan, Chengdu, China;
4.Dublin Institute for Advanced Studies, 31 Fitzwilliam Place, Dublin 2, Ireland;
5.Max-Planck-Institut for Nuclear Physics, P.O. Box 103980, Heidelberg, 69029, Germany;
6.State Key Laboratory of Particle Detection and Electronics, China;
7.University of Science and Technology of China, Anhui, Hefei, 230026, China;
8.School of Physical Science and Technology, School of Information Science and Technology, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China;
9.College of Physics, Sichuan University, Sichuan, Chengdu, 610065, China;
10.School of Astronomy and Space Science, Nanjing University, Jiangsu, Nanjing, 210023, China;
推荐引用方式
GB/T 7714
Pang, Binyu,Lv, Hongkui,Sheng, Xiangdong,et al. Time and charge calibration of the LHAASO electromagnetic particle detectors[C]. 见:. Virtual, Berlin, Germany. 2021-07-12.

入库方式: OAI收割

来源:云南天文台

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。