中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Optical testing of the primary mirror of the telescope of multispectral high-resolution imaging system

文献类型:会议论文

作者Li, Jing; Sun, Guoyan; Xue, Xun; Yan, Zhou; Zhao, Jianke
出版日期2023
会议日期2022-07-29
会议地点Changchun, China
关键词Optical testing compensator sensitive misalignment
卷号12507
DOI10.1117/12.2656049
英文摘要

The multispectral high-resolution imaging system is composed of four wide-spectrum cameras, which can detect targets in the visible, short-wave infrared, medium-wave infrared and long-wave infrared spectrum simultaneously. In order to reduce the size of the system, the four wide-spectrum cameras use the same telescope. To achieve operating wavelengths covering four wavebands, the telescope uses a fully reflective design with a coaxial aspherical surface with a hole in the center of the primary mirror. If aberration-free testing is used, the central aperture will occur, resulting in incomplete aperture of surface shape detection. Thus, in this paper, a compensator is designed which can achieve the whole aperture of surface testing without centralized obscuration. At the same time, the impact of the misalignment of compensator in the optical path during the test is analyzed. The optical testing path adopts infinite conjugate working distance to reduce one adjustment amount of compensator. And the first surface of compensator is coordinated with the interferometer to adjust the angle of compensator quickly and accurately, which further reduces the measurement error introduced by the optical testing path. The design of the compensator can realize the control of sensitive misalignment, reduce the surface measuring error caused by the compensator misalignments, and eventually reduce the precise processing error. © 2023 SPIE.

产权排序1
会议录Advanced Optical Manufacturing Technologies and Applications 2022; and 2nd International Forum of Young Scientists on Advanced Optical Manufacturing, AOMTA and YSAOM 2022
会议录出版者SPIE
语种英语
ISSN号0277786X;1996756X
ISBN号9781510661264
源URL[http://ir.opt.ac.cn/handle/181661/96338]  
专题先进光学元件试制中心
通讯作者Li, Jing
作者单位Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Science, Xi'an; 710119, China
推荐引用方式
GB/T 7714
Li, Jing,Sun, Guoyan,Xue, Xun,et al. Optical testing of the primary mirror of the telescope of multispectral high-resolution imaging system[C]. 见:. Changchun, China. 2022-07-29.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本