中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Charge reconstruction in large-area photomultipliers

文献类型:期刊论文

作者Grassi, M.; Montuschi, M.; Baldoncini, M.; Mantovani, F.; Ricci, B.; Andronico, G.; Antonelli, V.; Bellato, M.; Bernieri, E.; Brigatti, A.
刊名JOURNAL OF INSTRUMENTATION
出版日期2018
卷号13
关键词Calorimeter methods Liquid detectors Photon detectors for UV, visible and IR photons (vacuum) (photomultipliers HPDs, others) Scintillators, scintillation and light emission processes (solid gas and liquid scintillators)
ISSN号1748-0221
DOI10.1088/1748-0221/13/02/P02008
文献子类Article
英文摘要Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos' extremely elusive nature. Depending on the detector light yield, several scintillation photons stemming from the same neutrino interaction are likely to hit a single PMT in a few tens/hundreds of nanoseconds, resulting in several photoelectrons (PES) to pile-up at the PMT anode. In such scenario, the signal generated by each PE is entangled to the others, and an accurate PMT charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the PMT charge reconstruction in the case of large PE pile-up, providing an unbiased charge estimator at the permille level up to 15 detected PES. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both PMT and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions - such as an overshoot. The analysis of simulated p m t waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from 0.769 +/- 0.001 (without deconvolution) to 0.989 +/- 0.001 (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at [1].
学科主题Instruments & Instrumentation
语种英语
WOS记录号WOS:000424193900001
源URL[http://ir.ihep.ac.cn/handle/311005/297494]  
专题江门中微子实验
推荐引用方式
GB/T 7714
Grassi, M.,Montuschi, M.,Baldoncini, M.,et al. Charge reconstruction in large-area photomultipliers[J]. JOURNAL OF INSTRUMENTATION,2018,13.
APA Grassi, M..,Montuschi, M..,Baldoncini, M..,Mantovani, F..,Ricci, B..,...&Votano, L..(2018).Charge reconstruction in large-area photomultipliers.JOURNAL OF INSTRUMENTATION,13.
MLA Grassi, M.,et al."Charge reconstruction in large-area photomultipliers".JOURNAL OF INSTRUMENTATION 13(2018).

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。