中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A high-performance electrochemical sensor for sensitive detection of tetracycline based on a Zr-UiO-66/MWCNTs/AuNPs composite electrode

文献类型:期刊论文

作者Weng, Xueyu; Huang, Jingqi; Ye, Huazhu; Xu, He; Cai, Dongqing; Wang, Dongfang
刊名ANALYTICAL METHODS
出版日期2022-08-11
卷号14期号:31页码:3000-3010
关键词METAL-ORGANIC FRAMEWORKS CARBON NANOTUBES LIQUID-CHROMATOGRAPHY ADSORPTION ANTIBIOTICS BEHAVIOR WATER OXIDATION
ISSN号1759-9660
英文摘要Herein, a high-performance electrochemical sensor was constructed based on a metal-organic framework (Zr-UiO-66)/multi-carbon nanotubes/gold nanoparticles (Zr-UiO-66/MWCNTs/AuNPs) composite modified glassy carbon electrode for sensitive determination of tetracycline. The morphology, structure, and performance of Zr-UiO-66/MWCNTs/AuNPs were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive spectroscopy (EDS), Fourier transform infrared spectroscopy (FT-IR), and electrochemical techniques. The Zr-UiO-66/MWCNTs/AuNPs nanohybrids exhibited excellent electrocatalytic activity towards the oxidation of tetracycline, mainly because of the synergistic effect of the MOFs, MWCNTs, and gold nanoparticles. The electrochemical kinetics and catalytical mechanism of tetracycline were demonstrated, proving that tetracycline's electrocatalytic oxidation reaction was an absorption-controlled two-step process involving the transfer of two protons and two electrons, respectively. Furthermore, a simple and facile method was used to achieve the regeneration of the absorbed saturated electrode. A low concentration of tetracycline was detected by amperometry with the linear ranges of 5 x 10(-7) to 2.25 x 10(-4) mol L-1 (R-2 = 0.9941), the sensitivity was 45.4 mA L mol(-1), and the limit of detection was as low as 1.67 x 10(-7) mol L-1 (S/N = 3). In addition, the composite electrode demonstrated high selectivity (interference deviation of +/- 5%), satisfactory reproductivity (RSD of 5.31%), and long-term stability (easy regeneration) and was successfully applied in the analysis of tetracycline antibiotics in actual samples. Thus, the proposed electrode provides a promising and prospective MOFs-based sensing platform for the detection of tetracyclines in the environment.
源URL[https://ir.rcees.ac.cn/handle/311016/47450]  
专题生态环境研究中心_环境化学与生态毒理学国家重点实验室
通讯作者Xu, He
作者单位1.Univ Chinese Acad Sci, Coll Resources & Environm, Beijing 100049, Peoples R China
2.Donghua Univ, Coll Environm Sci & Engn, Shanghai 201620, Peoples R China
3.Chinese Acad Sci, State Key Lab Environm Chem & Ecotoxicol, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
推荐引用方式
GB/T 7714
Weng, Xueyu,Huang, Jingqi,Ye, Huazhu,et al. A high-performance electrochemical sensor for sensitive detection of tetracycline based on a Zr-UiO-66/MWCNTs/AuNPs composite electrode[J]. ANALYTICAL METHODS,2022,14(31):3000-3010.
APA Weng, Xueyu,Huang, Jingqi,Ye, Huazhu,Xu, He,Cai, Dongqing,&Wang, Dongfang.(2022).A high-performance electrochemical sensor for sensitive detection of tetracycline based on a Zr-UiO-66/MWCNTs/AuNPs composite electrode.ANALYTICAL METHODS,14(31),3000-3010.
MLA Weng, Xueyu,et al."A high-performance electrochemical sensor for sensitive detection of tetracycline based on a Zr-UiO-66/MWCNTs/AuNPs composite electrode".ANALYTICAL METHODS 14.31(2022):3000-3010.

入库方式: OAI收割

来源:生态环境研究中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。