Long-term direct ultrafiltration without chemical cleaning for purification of micro-polluted water in rural regions: Feasibility and application prospects
文献类型:期刊论文
作者 | Wu, Siqi; Lu, Chaojie; Ma, Baiwen; Liu, Ruiping; Hu, Chengzhi; Ulbricht, Mathias; Qu, Jiuhui |
刊名 | CHEMICAL ENGINEERING JOURNAL |
出版日期 | 2022-09-01 |
卷号 | 443期号:0页码:136531 |
ISSN号 | 1385-8947 |
关键词 | LOW-PRESSURE MEMBRANES FOULING MECHANISMS ORGANIC-MATTER FOULANTS BACKWASH REMOVAL CALCIUM SPECTRA OXIDE ACIDS |
英文摘要 | Water treatment technologies that feature a simple operation, affordable cost, and low chemical addition are necessary to achieve the goal of supplying clean water to rural regions. In this study, an automated-control direct ultrafiltration (UF) process without chemical cleaning was operated and investigated using the micro-polluted surface water at a mountain village in China as feed. During the approximately 2.5-year operation, the UF process operated steady without pretreatment and chemical cleaning, and clean drinking water that met the Chinese drinking water standard (GB 5749-2006) was continuously available. Despite occasional shock loading (84.7 NTU), the turbidity (the major contaminant of feed water) was low (0.3 +/- 0.1 NTU) in the effluent, and the filtration resistance remained at (14.7 +/- 0.7) x 1012 m(-1) except for the initial increase. Compared with organic substances, inorganic substances were dominant constituents of cake layer. Alumina or silica particles were easily removed by frequent backwashing and were distributed on the outer surface (newly formed) of cake layer. In contrast, the bulk cake layer was predominantly composed of CaCO(3 )scales, indicating its major role in membrane fouling. Regarding organic fouling, low-molecular-weight hydrophilic carbohydrate-like compounds, which were related to bacterial activities, were dominant compositions (91.5%). Proteobacteria made a major contribution to bacterial communities (52.2%). Because of the simple process (almost unattended) and no chemical cleaning, the operation and maintenance cost was only 5.3 cents.m(-3) during the entire operation. These findings demonstrate that direct UF without chemical cleaning has significant application potential in rural regions with micro-polluted water. |
源URL | [https://ir.rcees.ac.cn/handle/311016/47871] |
专题 | 生态环境研究中心_中国科学院饮用水科学与技术重点实验室 |
通讯作者 | Ma, Baiwen |
作者单位 | 1.Univ Duisburg Essen, Lehrstuhl Tech Chem 2, D-45117 Essen, Germany 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 3.Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China 4.Tsinghua Univ, Ctr Water & Ecol, Sch Environm, State Key Joint Lab Environm Simulat & Pollut Cont, Beijing 100084, Peoples R China |
推荐引用方式 GB/T 7714 | Wu, Siqi,Lu, Chaojie,Ma, Baiwen,et al. Long-term direct ultrafiltration without chemical cleaning for purification of micro-polluted water in rural regions: Feasibility and application prospects[J]. CHEMICAL ENGINEERING JOURNAL,2022,443(0):136531. |
APA | Wu, Siqi.,Lu, Chaojie.,Ma, Baiwen.,Liu, Ruiping.,Hu, Chengzhi.,...&Qu, Jiuhui.(2022).Long-term direct ultrafiltration without chemical cleaning for purification of micro-polluted water in rural regions: Feasibility and application prospects.CHEMICAL ENGINEERING JOURNAL,443(0),136531. |
MLA | Wu, Siqi,et al."Long-term direct ultrafiltration without chemical cleaning for purification of micro-polluted water in rural regions: Feasibility and application prospects".CHEMICAL ENGINEERING JOURNAL 443.0(2022):136531. |
入库方式: OAI收割
来源:生态环境研究中心
浏览0
下载0
收藏0
其他版本