中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Design of Fourier ptychographic illuminator for single full-FOV reconstruction

文献类型:期刊论文

作者Gao, Yuting1,2,3; Pan, An2,3; Gao, Huiqin2,3; Wang, Aiye2,3; Ma, Caiwen1,2; Yao, Baoli2,3
刊名OPTICS EXPRESS
出版日期2023-08-28
卷号31期号:18页码:29826-29842
ISSN号1094-4087
DOI10.1364/OE.500385
产权排序1
英文摘要

Fourier ptychographic microscopy (FPM) is a spatial-temporal-modulation high-throughput imaging technique via a sequential angle-varied LED illumination. Therefore, the illuminator is one of the key components and the design of this illuminator is significant. However, because of the property of spherical wave, partial coherence, and aperture-induced vignetting, the acquired images must be processed in blocks first, and rely on parallel reconstruction via a graphics processing unit (GPU). The high cost makes it unappealing compared with commercial whole slide imaging system via a low-cost central processing unit (CPU). Especially, the vignetting severely destroys the space-invariant model and induces obvious artifacts in FPM, which is the most difficult problem. The conventional method is to divide the field of view (FOV) into many tiles and omit those imperfect images, which is crude and may discards low frequency information. In this paper, we reevaluated the conditions of vignetting in FPM. Through our analysis, the maximum side length of FOV is 0.759 mm for a single full-FOV reconstruction via a 4x/0.1 NA objective and a 4 mm spacing LED array in theory, while almost 1.0 mm can be achieved in practice due to the tolerance of algorithm. We found that FPM system can treat the vignetting coefficient Vf below 0.1 as brightfield images and Vf lager than 0.9 as darkfield images, respectively. We reported an optimized distribution for designing an illuminator without vignetting effect according to the off-the-shelf commercial products, which can reconstruct full FOV in one time via a CPU. By adjusting the distribution of LED units, the system could retrieve the object with the side length of FOV up to 3.8 mm for a single full-FOV reconstruction, which achieves the largest FOV that a typical 4x/0.1 NA objective with the field number of 22 mm can afford.& COPY; 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

语种英语
出版者Optica Publishing Group
WOS记录号WOS:001070170400003
源URL[http://ir.opt.ac.cn/handle/181661/96798]  
专题西安光学精密机械研究所_瞬态光学技术国家重点实验室
通讯作者Pan, An
作者单位1.Chinese Acad Sci, Key Lab Space Precis Measurement Technol, Xian 710119, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
3.Chinese Acad Sci, State Key Lab Transient Opt & Photon, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
推荐引用方式
GB/T 7714
Gao, Yuting,Pan, An,Gao, Huiqin,et al. Design of Fourier ptychographic illuminator for single full-FOV reconstruction[J]. OPTICS EXPRESS,2023,31(18):29826-29842.
APA Gao, Yuting,Pan, An,Gao, Huiqin,Wang, Aiye,Ma, Caiwen,&Yao, Baoli.(2023).Design of Fourier ptychographic illuminator for single full-FOV reconstruction.OPTICS EXPRESS,31(18),29826-29842.
MLA Gao, Yuting,et al."Design of Fourier ptychographic illuminator for single full-FOV reconstruction".OPTICS EXPRESS 31.18(2023):29826-29842.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。