中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion

文献类型:期刊论文

作者Yang, Zewen4; Zhang, Lu4; Liu, Tong4; Wu, Haoyu4; Tang, Zhiyuan3; Fan, Chen4; Liu, Xiaolong2; Zhang, Zhenxi1; Zhao, Hong4
刊名Biomedical Optics Express
出版日期2023
卷号14期号:9页码:4696-4712
ISSN号21567085
DOI10.1364/BOE.497681
产权排序2
英文摘要

LED array microscopy is a novel computational imaging technique that can achieve two-dimensional (2D) phase imaging and three-dimensional (3D) refractive index imaging with both high resolution and a large field of view. Although its experimental setup is simple, the errors caused by LED array position and light source central wavelength obviously decrease the quality of reconstructed results. To solve this problem, comprehensive error parameters optimized by the phase smoothing criterion are put forward in this paper. The central wavelength error and 3D misalignment model with six freedom degree errors of LED array are considered as the comprehensive error parameters when the spatial positional and optical features of arbitrarily placed LED array are unknown. Phase smoothing criterion is also introduced to the cost function for optimizing comprehensive error parameters to improve the convergence results. Compared with current system correction methods, the simulation and experimental results show that the proposed method in this paper has the best reconstruction accuracy, which can be well applied to an LED array microscope system with unknown positional and optical features of the LED array. © 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement.

语种英语
出版者Optica Publishing Group (formerly OSA)
源URL[http://ir.opt.ac.cn/handle/181661/96797]  
专题西安光学精密机械研究所_先进光学仪器研究室
通讯作者Zhang, Lu
作者单位1.Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi’an Jiaotong University, Xi’an; 710049, China
2.Mengchao Hepatobiliary Hospital of Fujian Medical University, The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Fuzhou; 350025, China;
3.Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an; 710119, China;
4.State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an; 710049, China;
推荐引用方式
GB/T 7714
Yang, Zewen,Zhang, Lu,Liu, Tong,et al. LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion[J]. Biomedical Optics Express,2023,14(9):4696-4712.
APA Yang, Zewen.,Zhang, Lu.,Liu, Tong.,Wu, Haoyu.,Tang, Zhiyuan.,...&Zhao, Hong.(2023).LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion.Biomedical Optics Express,14(9),4696-4712.
MLA Yang, Zewen,et al."LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion".Biomedical Optics Express 14.9(2023):4696-4712.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本