中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Numerical simulation of dual MCP hard x-ray imaging detector on spatial resolution and detection quantum efficiency

文献类型:会议论文

作者Liu, Yiheng2,3,4; Li, Lili2,3,4; Chen, Ping2,4; Zhang, Feng1; Gou, Yongsheng4; He, Kai4; Tian, Jinshou2,4
出版日期2022-11-11
会议日期2022-11-11
会议地点Changsha, PEOPLES R CHINA
关键词micro-channel plate X-ray framing camera Compton radiography detection quantum efficiency spatial resolution
DOI10.1117/12.2666993
英文摘要

Compton radiography is an important diagnostic tool for inertial confinement fusion (ICF), which provides important parameters about integrity, symmetry and.R areal density of the dense cold fuel surrounding the hot spot. The dual MCPs (micro-channel plate) configuration detector as a key component for Compton radiography has the ability to detect hard x-rays at energies from 40 to 200 keV with higher detective quantum efficiency (DQE). In this work, a set of simulation methods for calculating the DQE and spatial resolution of dual MCPs are proposed. The photoelectric conversion and secondary electron multiplication processes of 59 KeV X-rays in double MCPs were simulated. The first piece of MCP with 51% lead content absorb x-rays volumetrically to improve the DQE and the second piece of MCP provides a large gain to multiply the secondary electrons. The simulation results indicate that the spatial resolution of the dual MCP detector is 186 mu m, and the DQE can reach 6.2%, which will ensure the dual MCP-based framing cameras can obtain imploded capsule images with higher signal-to-noise ratio and spatial resolution. The influence of MCP parameters on DQE and spatial resolution was analyzed, and the simulation method will provide an important reference for further optimization of the detector.

产权排序1
会议录ADVANCED FIBER LASER CONFERENCE, AFL2022
会议录出版者SPIE-INT SOC OPTICAL ENGINEERING
语种英语
ISSN号0277-786X;1996-756X
ISBN号978-1-5106-6314-5; 978-1-5106-6315-2
WOS记录号WOS:001055604400012
源URL[http://ir.opt.ac.cn/handle/181661/96807]  
专题条纹相机工程中心
通讯作者Chen, Ping; Tian, Jinshou
作者单位1.China Acad Engn Phys, Mianyang 621900, Sichuan, Peoples R China
2.Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
4.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Key Lab Ultra fast photoelectr Diagnost Technol, Xian 710119, Peoples R China
推荐引用方式
GB/T 7714
Liu, Yiheng,Li, Lili,Chen, Ping,et al. Numerical simulation of dual MCP hard x-ray imaging detector on spatial resolution and detection quantum efficiency[C]. 见:. Changsha, PEOPLES R CHINA. 2022-11-11.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。