中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A 96-well plate UV fluorometer based on micro fluorescence detector array and dynamic zero correction algorithm

文献类型:期刊论文

作者Wang, Chuanliang2,3; Geng, Xuhui3; Gao, Yan3; Zheng, Chao3; Guan, Yafeng1,3
刊名TALANTA
出版日期2023-12-01
卷号265页码:6
ISSN号0039-9140
关键词96-Well plate UV fluorometer Micro fluorescence detector array Dynamic zero correction algorithm
DOI10.1016/j.talanta.2023.124922
通讯作者Geng, Xuhui(xhgeng@dicp.ac.cn) ; Guan, Yafeng(guanyafeng@dicp.ac.cn)
英文摘要A 96-well plate UV fluorometer was developed and evaluated. Eight micro fluorescence detectors close to each other were used as detector array for 8 channels. Each detector employed an UV light emitting diode (LED) as light source and a photodiode (PD) with an amplifier circuit as optoelectronic detector. The optical paths of the detectors were designed by ray tracing method to avoid crosstalk between wells. Simultaneously scanning and detecting of 8 channels saves scanning time and improves detection efficiency. The scanning time of the 96-well plate was about 80 s. A dynamic zero correction algorithm was proposed to solve the problem of measurement accuracy reduction caused by the background fluorescence differences between plates and wells under irradia-tion of UV light. The measurement repeatability (RSD) for 1 & mu;g/L 7-Diethylamino-4-methylcoumarin sample was 2.25%. Compared with the fixed zero correction method, the limit of detection (LOD), measurement repeat-ability, and average relative error were improved by 3.3, 2.7, and 4.5 times, respectively. The proposed method is robust and can be applied to different analysis systems. The developed fluorometer has great potential in high-throughput rapid detection of food safety and life sciences.
WOS关键词LIGHT-EMITTING DIODE ; DETECTION SYSTEM ; READER
资助项目General Program of the National Natural Science Foundation of China[22074146] ; Youth Innovation Promotion Association of the Chinese Academy of Sciences[2019186] ; DICP Innovation Funding[I202014] ; DICP[DICP I202014]
WOS研究方向Chemistry
语种英语
出版者ELSEVIER
WOS记录号WOS:001048128700001
资助机构General Program of the National Natural Science Foundation of China ; Youth Innovation Promotion Association of the Chinese Academy of Sciences ; DICP Innovation Funding ; DICP
源URL[http://ir.idsse.ac.cn/handle/183446/10445]  
专题深海科学研究部
通讯作者Geng, Xuhui; Guan, Yafeng
作者单位1.Chinese Acad Sci, Inst Deep Sea Sci & Engn, 28 Luhuitou Rd, Sanya 572000, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
3.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Deep Sea Composit Detect Technol Liaoning, Dept Instrumentat & Analyt Chem,CAS Key Lab Separa, 457 Zhongshan Rd, Dalian 116023, Peoples R China
推荐引用方式
GB/T 7714
Wang, Chuanliang,Geng, Xuhui,Gao, Yan,et al. A 96-well plate UV fluorometer based on micro fluorescence detector array and dynamic zero correction algorithm[J]. TALANTA,2023,265:6.
APA Wang, Chuanliang,Geng, Xuhui,Gao, Yan,Zheng, Chao,&Guan, Yafeng.(2023).A 96-well plate UV fluorometer based on micro fluorescence detector array and dynamic zero correction algorithm.TALANTA,265,6.
MLA Wang, Chuanliang,et al."A 96-well plate UV fluorometer based on micro fluorescence detector array and dynamic zero correction algorithm".TALANTA 265(2023):6.

入库方式: OAI收割

来源:深海科学与工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。