中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Application of triple potential step amperometry method for quantitative electroanalysis

文献类型:期刊论文

作者Liu ChenMing; Cao HongBin; Li YuPing; Zhang Yi
刊名CHINESE SCIENCE BULLETIN
出版日期2007-10-01
卷号52期号:20页码:2771-2774
ISSN号1001-6538
关键词triple potential step amperometry enzyme-modified electrode nitroreductase electroanalysis
其他题名Chin. Sci. Bull.
中文摘要A novel quantitative electroanalysis method, triple potential step amperometry (TPSA), was developed and explained with an example of nitrobenzene analyzing in water. The selectivity of TPSA was improved by controlling the potential step within a narrow interval and using enzyme-modified electrode, the narrow potential step makes the method avoid most interferents, and enzyme-modified electrode can enhance the response of target substance selectively. The peak area was investigated for quantitative calibration, such as nitrobenzene concentration showing a linear relation with the peak area, with the correlation coefficients being 0.9995. The t-test and F-test were applied to evaluating the reliability of TPSA, the results showed that there was no evidence of systematic error for TPSA, and the method was of no significant difference from CV. The merit of fast detecting and few potential changing times make the TPSA suitably applicable to low-cost automatic monitoring equipments.
英文摘要A novel quantitative electroanalysis method, triple potential step amperometry (TPSA), was developed and explained with an example of nitrobenzene analyzing in water. The selectivity of TPSA was improved by controlling the potential step within a narrow interval and using enzyme-modified electrode, the narrow potential step makes the method avoid most interferents, and enzyme-modified electrode can enhance the response of target substance selectively. The peak area was investigated for quantitative calibration, such as nitrobenzene concentration showing a linear relation with the peak area, with the correlation coefficients being 0.9995. The t-test and F-test were applied to evaluating the reliability of TPSA, the results showed that there was no evidence of systematic error for TPSA, and the method was of no significant difference from CV. The merit of fast detecting and few potential changing times make the TPSA suitably applicable to low-cost automatic monitoring equipments.
WOS标题词Science & Technology
类目[WOS]Multidisciplinary Sciences
研究领域[WOS]Science & Technology - Other Topics
关键词[WOS]MULTISTEP ELECTRODE PROCESSES ; DIFFUSION-COEFFICIENTS ; ELECTROCHEMICAL DEPLETION ; SPHERICAL ELECTRODES ; NITROBENZENE ; CHRONOAMPEROMETRY ; BENZENE ; WATER ; LAYER
收录类别SCI
原文出处://WOS:000249986200006
语种英语
WOS记录号WOS:000249986200006
公开日期2013-10-15
版本出版稿
源URL[http://ir.ipe.ac.cn/handle/122111/3384]  
专题过程工程研究所_研究所(批量导入)
作者单位1.Chinese Acad Sci, Inst Proc Engn, Beijing 100080, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Liu ChenMing,Cao HongBin,Li YuPing,et al. Application of triple potential step amperometry method for quantitative electroanalysis[J]. CHINESE SCIENCE BULLETIN,2007,52(20):2771-2774.
APA Liu ChenMing,Cao HongBin,Li YuPing,&Zhang Yi.(2007).Application of triple potential step amperometry method for quantitative electroanalysis.CHINESE SCIENCE BULLETIN,52(20),2771-2774.
MLA Liu ChenMing,et al."Application of triple potential step amperometry method for quantitative electroanalysis".CHINESE SCIENCE BULLETIN 52.20(2007):2771-2774.

入库方式: OAI收割

来源:过程工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。