中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study

文献类型:期刊论文

作者Liang, Xiuzuo,,,; Shuai, Lei,,,; Liu, Yantao,,; Li, Xin,,; Kong, Lingqin,,; Wei, Qing,,; Wang, Yingjie,,; Zhang, Zhiming,,,; Huang, Xianchao,,,; Hu, Xuanhou,,
刊名Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
出版日期2022
卷号1044页码:167503
ISSN号0168-9002
DOI10.1016/j.nima.2022.167503
文献子类Article
英文摘要In the study of this paper, based on the symmetry of regular icosahedron, a spherical detector system for 4π field-of-view (FOV) gamma imaging was proposed based on 80 GAGG (Ce:GAGG, Gd3Al2Ga3O12) scintillator pixels. The spherical detector system combines both coded aperture (CA) and Compton imaging (CI) modalities. The detector system was simulated precisely with an experimental test of one representative GAGG pixel. Several radionuclides with characteristic energy ranging from 59.5 keV to 1.33 MeV were imaged under the far-field situation. Both imaging modes realize the 4π view while the coded aperture method achieves a higher image quality for radioactive sources with lower energy and the Compton method performs conversely. The imaging system can localize a 10 mCi 137Cs point source at 10 m within 1 s in the two modes and the Compton imaging mode reaches a high detection efficiency of up to 200 cps/μSv/h for 137Cs. And the angular estimation full-width-at-half-maximum (FWHM) was approximately 5.2°for coded aperture mode and 14°for Compton mode. The angular resolution was evaluated to be better than 30°. The high intrinsic imaging sensitivity and reasonable imaging quality make this detector system design attractive for far-field radiation imaging. © 2022 Elsevier B.V.
电子版国际标准刊号1872-9576
语种英语
源URL[http://ir.ihep.ac.cn/handle/311005/300033]  
专题高能物理研究所_核技术应用研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Liang, Xiuzuo,,,,Shuai, Lei,,,,Liu, Yantao,,,et al. Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study[J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2022,1044:167503.
APA Liang, Xiuzuo,,,.,Shuai, Lei,,,.,Liu, Yantao,,.,Li, Xin,,.,Kong, Lingqin,,.,...&Wei, Long,,,.(2022).Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study.Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,1044,167503.
MLA Liang, Xiuzuo,,,,et al."Coded aperture and Compton imaging capability of spherical detector system design based on GAGG scintillators: A Monte Carlo study".Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1044(2022):167503.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本