中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions

文献类型:期刊论文

作者Zeng Si-xian2; Ren Xin2; He Hao-xuan2; Nie Wei1,2
刊名SPECTROSCOPY AND SPECTRAL ANALYSIS
出版日期2023-09-01
卷号43
ISSN号1000-0593
关键词Spectral line-shape profile TDLAS Integral absorbance Speed-averaged line-width Doppler HWHM (Half-width-at-half-maximum) Temperature
DOI10.3964/j.issn.1000-0593(2023)09-2715-07
通讯作者Nie Wei(niewei@scut.edu.cn)
英文摘要To achieve high-precision spectral retrieval under high-temperature conditions, we compared and analyzed the accuracy and stability of seven different spectral line-shape profiles and developed a spectral line-shape profile selection strategy suitable for high-temperature diagnosis. Firstly, two H2O absorption spectra in the temperature range of 1 100 similar to 1 600 K were measured experimentally, and seven different spectral profiles were used to fit them respectively. The integral absorbance, velocity-dependent line-width and Doppler half height and half-width (FWHM) of each measured spectrum were obtained, and the gas temperature value was calculated according to the line-intensity ratio method. The comparative analysis show that under the condition of high temperature and atmospheric pressure, the fitting accuracy of the Gaussian profile is the worst, and the gas temperature inversion accuracy of the Gaussian profile is the highest; Setting the Doppler half-height width parameter in the line-shape profile as a constant can not only effectively improve the stability and accuracy of spectral line parameter inversion, but also improve the temperature inversion accuracy of each spectral line-shape profile. Compared with the non-Voigt profile (speed-dependent Voigt profile, Rautian profile, Speed-dependent Rautian profile and Hartman tran profile), the integral absorbance and velocity-dependent line-width obtained by the Voigt profile are small, and the relative error of calculated temperature are large. Finally, the running time of seven line-shape profile fitting programs was compared. Under the condition of ensuring accuracy, the speed-dependent Voigt profile calculation speed is the fastest. Therefore, the gas temperature is obtained by Gaussian Profile. The Doppler half height and half width are calculated according to the temperature and fixed as a constant, and the speed-dependent Voigt profile is used to fit the measured spectrum, which can effectively improve the inversion accuracy, velocity and stability of high-temperature spectrum.
WOS关键词DEPENDENT LINESHAPE PARAMETERS ; DIODE-LASER MEASUREMENTS ; H2O TRANSITIONS ; ABSORPTION ; VOIGT ; LINESTRENGTH ; GALATRY ; CO2
WOS研究方向Spectroscopy
语种英语
出版者OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS
WOS记录号WOS:001064031800010
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/133520]  
专题中国科学院合肥物质科学研究院
通讯作者Nie Wei
作者单位1.Chinese Acad Sci, Hefei Inst Phys Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China
2.South China Univ Technol, Sch Elect Power, Guangzhou 510641, Peoples R China
推荐引用方式
GB/T 7714
Zeng Si-xian,Ren Xin,He Hao-xuan,et al. Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2023,43.
APA Zeng Si-xian,Ren Xin,He Hao-xuan,&Nie Wei.(2023).Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions.SPECTROSCOPY AND SPECTRAL ANALYSIS,43.
MLA Zeng Si-xian,et al."Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions".SPECTROSCOPY AND SPECTRAL ANALYSIS 43(2023).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。