Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions
文献类型:期刊论文
作者 | Zeng Si-xian2; Ren Xin2; He Hao-xuan2; Nie Wei1,2 |
刊名 | SPECTROSCOPY AND SPECTRAL ANALYSIS |
出版日期 | 2023-09-01 |
卷号 | 43 |
ISSN号 | 1000-0593 |
关键词 | Spectral line-shape profile TDLAS Integral absorbance Speed-averaged line-width Doppler HWHM (Half-width-at-half-maximum) Temperature |
DOI | 10.3964/j.issn.1000-0593(2023)09-2715-07 |
通讯作者 | Nie Wei(niewei@scut.edu.cn) |
英文摘要 | To achieve high-precision spectral retrieval under high-temperature conditions, we compared and analyzed the accuracy and stability of seven different spectral line-shape profiles and developed a spectral line-shape profile selection strategy suitable for high-temperature diagnosis. Firstly, two H2O absorption spectra in the temperature range of 1 100 similar to 1 600 K were measured experimentally, and seven different spectral profiles were used to fit them respectively. The integral absorbance, velocity-dependent line-width and Doppler half height and half-width (FWHM) of each measured spectrum were obtained, and the gas temperature value was calculated according to the line-intensity ratio method. The comparative analysis show that under the condition of high temperature and atmospheric pressure, the fitting accuracy of the Gaussian profile is the worst, and the gas temperature inversion accuracy of the Gaussian profile is the highest; Setting the Doppler half-height width parameter in the line-shape profile as a constant can not only effectively improve the stability and accuracy of spectral line parameter inversion, but also improve the temperature inversion accuracy of each spectral line-shape profile. Compared with the non-Voigt profile (speed-dependent Voigt profile, Rautian profile, Speed-dependent Rautian profile and Hartman tran profile), the integral absorbance and velocity-dependent line-width obtained by the Voigt profile are small, and the relative error of calculated temperature are large. Finally, the running time of seven line-shape profile fitting programs was compared. Under the condition of ensuring accuracy, the speed-dependent Voigt profile calculation speed is the fastest. Therefore, the gas temperature is obtained by Gaussian Profile. The Doppler half height and half width are calculated according to the temperature and fixed as a constant, and the speed-dependent Voigt profile is used to fit the measured spectrum, which can effectively improve the inversion accuracy, velocity and stability of high-temperature spectrum. |
WOS关键词 | DEPENDENT LINESHAPE PARAMETERS ; DIODE-LASER MEASUREMENTS ; H2O TRANSITIONS ; ABSORPTION ; VOIGT ; LINESTRENGTH ; GALATRY ; CO2 |
WOS研究方向 | Spectroscopy |
语种 | 英语 |
出版者 | OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS |
WOS记录号 | WOS:001064031800010 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/133520] |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Nie Wei |
作者单位 | 1.Chinese Acad Sci, Hefei Inst Phys Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China 2.South China Univ Technol, Sch Elect Power, Guangzhou 510641, Peoples R China |
推荐引用方式 GB/T 7714 | Zeng Si-xian,Ren Xin,He Hao-xuan,et al. Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2023,43. |
APA | Zeng Si-xian,Ren Xin,He Hao-xuan,&Nie Wei.(2023).Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions.SPECTROSCOPY AND SPECTRAL ANALYSIS,43. |
MLA | Zeng Si-xian,et al."Influence Analysis of Spectral Line-Shape Models on Spectral Diagnoses Under High-Temperature Conditions".SPECTROSCOPY AND SPECTRAL ANALYSIS 43(2023). |
入库方式: OAI收割
来源:合肥物质科学研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。