Thermodynamic analysis of the heat pump steam system with medium-low temperature heat source
文献类型:期刊论文
作者 | Li, Shuaiqi1,2; He, Shihui1![]() ![]() |
刊名 | ENERGY REPORTS
![]() |
出版日期 | 2021-11-01 |
卷号 | 7页码:266-278 |
关键词 | Low-grade heat source Cascade heat pump Steam generator Thermodynamic analysis |
ISSN号 | 2352-4847 |
DOI | 10.1016/j.egyr.2021.10.032 |
通讯作者 | Feng, Zipping(fengzp@ms.giec.ac.cn) |
英文摘要 | Heat Pump Steam technology driven by electric power has an important application value in the industrial thermal field. A cascade air source heat pump steam system (CASGHP) using in thermal workshop is proposed in this paper. A numerical model is established by EES software. The thermal performances of several feasible refrigerants in the cascade system are analyzed comparatively. The influences of intermediate cooling temperature (T-intc), the injection temperature (T-inje), the evaporating temperature (T-evap), the outlet steam temperature (T-out), gas-injection ratio (beta(g)) and specific rate of compressors pressure ratio (PRR) on system power consumption of generating a ton steam (W-per) and system COP are studied. The conclusions are as follows: When R134a is used in low temperature section of the cascade system, R245fa, R1234ze(Z) and R1336mzz(Z) used in high temperature section respectively can meet the requirements of steam generation. The COP of the CASGHP adopted R1234ze(Z) is the largest, followed by R245fa and R1336mzz(Z). There exists a maximum COP, which is 2.268, 2.286 and 2.211, respectively. When Tevap is 10. C and Tout is 120 degrees C, the optimal T-intc of CASGHP with these high temperature refrigerants is 53. C, 50.C and 53. C, the optimal Tinje is 79.C, 78.5 and 85.5, the optimal beta(g) is 0.207, 0.18 and 0.165, and the optimal PRR is 0.77, 0.71 and 0.972, respectively. The COP increases by 18.4%, 18.2% and 17.9% respectively when Tevap increases from 10 degrees C to 30 degrees C, but it decreases by 14.4%, 14.2% and 10.2% respectively when Tout increases from 100 degrees C to 120 degrees C. (C) 2021 TheAuthor(s). Published by Elsevier Ltd. |
资助项目 | Guangzhou Science and Technology Program of China[201903010029] |
WOS研究方向 | Energy & Fuels |
语种 | 英语 |
WOS记录号 | WOS:000756699200024 |
出版者 | ELSEVIER |
资助机构 | Guangzhou Science and Technology Program of China |
源URL | [http://ir.giec.ac.cn/handle/344007/35851] ![]() |
专题 | 中国科学院广州能源研究所 |
通讯作者 | Feng, Zipping |
作者单位 | 1.Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Guangdong, Peoples R China 2.Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Shuaiqi,He, Shihui,Song, Wenji,et al. Thermodynamic analysis of the heat pump steam system with medium-low temperature heat source[J]. ENERGY REPORTS,2021,7:266-278. |
APA | Li, Shuaiqi,He, Shihui,Song, Wenji,&Feng, Zipping.(2021).Thermodynamic analysis of the heat pump steam system with medium-low temperature heat source.ENERGY REPORTS,7,266-278. |
MLA | Li, Shuaiqi,et al."Thermodynamic analysis of the heat pump steam system with medium-low temperature heat source".ENERGY REPORTS 7(2021):266-278. |
入库方式: OAI收割
来源:广州能源研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。