中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Influence of finite coherence of injected light on ring-down cavity measurement method and intensity integral method for ring-down time determination

文献类型:期刊论文

作者Huang, Zhi-Qiu2,3; Zhang, Meng2,3; Peng, Zhi-Min2,3; Wang, Zhen1; Yang, Qian-Suo2,3; Yang QS(杨乾锁); Peng ZM(彭志敏)
刊名ACTA PHYSICA SINICA
出版日期2023-09-20
卷号72期号:18页码:10
ISSN号1000-3290
关键词cavity ring-down spectroscopy light coherence ring-down time intensity integration
DOI10.7498/aps.72.20230448
通讯作者Yang, Qian-Suo(qsyang@imech.ac.cn)
英文摘要Using numerical simulation and a constructed cavity ring-down spectroscopy device, the influence of the finite coherence of the injected laser on the coupling process between the injected light and the cavity longitudinal mode is studied. The finite coherence of the injected light leads to the randomness of the coupling pulse during frequency scanning. The randomness is mainly reflected in two aspects. One is that as the coherence length decreases, the random amplitude range of the coupling pulse increases, and the other is that as the coherence of the injected light deteriorates, the coupling pulse changes from a single pulse with intensity evolution into continuous multiple pulses, and the overall width gradually increases with the decrease of the scanning rate. Moreover, with the deterioration of the coherence, when the light intensity of the cavity is used to turn off the injected light, the decrease in the scanning rate can cause more than one injection shut-off and ring-down event in a frequency coupling process, especially when scanning with the length of the cavity. In addition, a theoretical method is proposed to estimate the ring-down time by using the strength integral of different time intervals, and the relevant experimental verification is carried out. The experimental results show that the relative error of the ring-down time obtained by the intensity integration method is smaller than that obtained by the traditional fitting method.
WOS关键词SPECTROSCOPY ; LASER ; SPECTROMETER ; ALGORITHM ; CRDS
WOS研究方向Physics
语种英语
WOS记录号WOS:001089241700014
源URL[http://dspace.imech.ac.cn/handle/311007/93294]  
专题力学研究所_高温气体动力学国家重点实验室
通讯作者Yang, Qian-Suo
作者单位1.Tsinghua Univ, Dept Energy & Power Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
2.Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China
3.Chinese Acad Sci, Key Lab Mech Fluid Solid Coupling Syst, Inst Mech, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Huang, Zhi-Qiu,Zhang, Meng,Peng, Zhi-Min,et al. Influence of finite coherence of injected light on ring-down cavity measurement method and intensity integral method for ring-down time determination[J]. ACTA PHYSICA SINICA,2023,72(18):10.
APA Huang, Zhi-Qiu.,Zhang, Meng.,Peng, Zhi-Min.,Wang, Zhen.,Yang, Qian-Suo.,...&彭志敏.(2023).Influence of finite coherence of injected light on ring-down cavity measurement method and intensity integral method for ring-down time determination.ACTA PHYSICA SINICA,72(18),10.
MLA Huang, Zhi-Qiu,et al."Influence of finite coherence of injected light on ring-down cavity measurement method and intensity integral method for ring-down time determination".ACTA PHYSICA SINICA 72.18(2023):10.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。