中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Annular sampling cylindrical vector beam polarization measurement error analysis based on the Stokes parameter method

文献类型:会议论文

作者Chang, Lingying2; Chi, Liang2; Chen, Kui2; Qiu, Yuehong1; Li, Jiayi2; Zhang, Youbiao2
出版日期2023
会议日期2023-07-25
会议地点Beijing, China
关键词cylindrical vector beams polarization detection measurement error AOP
卷号12959
DOI10.1117/12.3007450
英文摘要

Cylindrical vector beams(CVBs) are spatially non-uniform polarization distributions. It has been widely used in microscopic imaging, particle manipulation, beam shaping, and other fields. Accurate measurement of the CVBs polarization state distribution is one of the research problems. In order to analyze the influence of systematic errors on the CVBs polarization parameters, the measurement errors of the polarization azimuthal AOP under annular sampling are investigated in this paper. Firstly, the generation of CVBs and the measurement principle of Stokes parametric method is introduced; secondly, the radial and angular vector beam intensity images and the AOP distribution under different annular sampling are simulated; then, the variation of R=256 intensity error IΔ with the polarization azimuth error θ in the range of [-2°,2°] is analyzed. Finally, the single error and the coupling error are analyzed and discussed. The simulation results show that the intensity errors IΔ1 and IΔ2 are the same with the θ, and IΔ3 and IΔ4 are the same with the θ. Under the single error, the absolute error values of the AOPs with mutual residual angles are similar. The maximum absolute error of AOP of IΔ1 and IΔ2 is 1° (@45°) and the maximum relative error is 2.59% (@30°); the maximum absolute error of AOP of IΔ3 and IΔ4 is 1°(@0°) and the maximum relative error is 5.12% (@15°). Under the coupling error, the absolute AOP error of IΔ1 and IΔ2 increases with the increase θ, with the maximum value of 2° (@45°) and the maximum relative error of 5.25% (@30°); the absolute AOP error of IΔ3 and IΔ4 decreases with the increase of θ, with the maximum value of 2°(@0°), with a relative maximum error of 10.40% (@15°). The study provides an error data reference for CVBs polarization detection. It can provide technical support for the application of CVBs in different fields. © 2023 SPIE.

产权排序2
会议录AOPC 2023: Laser Technology and Applications; and Optoelectronic Devices and Integration
会议录出版者SPIE
语种英语
ISSN号0277786X;1996756X
ISBN号9781510672246
源URL[http://ir.opt.ac.cn/handle/181661/97145]  
专题西安光学精密机械研究所_空间光学应用研究室
通讯作者Chi, Liang
作者单位1.Xi'an institute of optics and precision mechanics of CAS, Xi'an; 710119, China
2.School of Electronic Engineering, Xi'an University of Posts and Telecommunications, Xi'an; 710121, China;
推荐引用方式
GB/T 7714
Chang, Lingying,Chi, Liang,Chen, Kui,et al. Annular sampling cylindrical vector beam polarization measurement error analysis based on the Stokes parameter method[C]. 见:. Beijing, China. 2023-07-25.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。