中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Rapid Determination of Positive-Negative Bacterial Infection Based on Micro-Hyperspectral Technology

文献类型:期刊论文

作者Du, Jian1,2; Tao, Chenglong1,2; Qi, Meijie1,2; Hu, Bingliang1,2; Zhang, Zhoufeng1,2
刊名SENSORS
出版日期2024-01
卷号24期号:2
ISSN号1424-8220
关键词micro-hyperspectral technology bacterial infection positive-negative determination spectral feature directly smeared urine sample deep learning
DOI10.3390/s24020507
产权排序1
英文摘要

To meet the demand for rapid bacterial detection in clinical practice, this study proposed a joint determination model based on spectral database matching combined with a deep learning model for the determination of positive-negative bacterial infection in directly smeared urine samples. Based on a dataset of 8124 urine samples, a standard hyperspectral database of common bacteria and impurities was established. This database, combined with an automated single-target extraction, was used to perform spectral matching for single bacterial targets in directly smeared data. To address the multi-scale features and the need for the rapid analysis of directly smeared data, a multi-scale buffered convolutional neural network, MBNet, was introduced, which included three convolutional combination units and four buffer units to extract the spectral features of directly smeared data from different dimensions. The focus was on studying the differences in spectral features between positive and negative bacterial infection, as well as the temporal correlation between positive-negative determination and short-term cultivation. The experimental results demonstrate that the joint determination model achieved an accuracy of 97.29%, a Positive Predictive Value (PPV) of 97.17%, and a Negative Predictive Value (NPV) of 97.60% in the directly smeared urine dataset. This result outperformed the single MBNet model, indicating the effectiveness of the multi-scale buffered architecture for global and large-scale features of directly smeared data, as well as the high sensitivity of spectral database matching for single bacterial targets. The rapid determination solution of the whole process, which combines directly smeared sample preparation, joint determination model, and software analysis integration, can provide a preliminary report of bacterial infection within 10 min, and it is expected to become a powerful supplement to the existing technologies of rapid bacterial detection.

语种英语
出版者MDPI
WOS记录号WOS:001150870900001
源URL[http://ir.opt.ac.cn/handle/181661/97189]  
专题西安光学精密机械研究所_光学影像学习与分析中心
通讯作者Zhang, Zhoufeng
作者单位1.Xian Key Lab Biomed Spect, Xian 710119, Peoples R China
2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Key Lab Spectral Imaging Technol CAS, Xian 710119, Peoples R China
推荐引用方式
GB/T 7714
Du, Jian,Tao, Chenglong,Qi, Meijie,et al. Rapid Determination of Positive-Negative Bacterial Infection Based on Micro-Hyperspectral Technology[J]. SENSORS,2024,24(2).
APA Du, Jian,Tao, Chenglong,Qi, Meijie,Hu, Bingliang,&Zhang, Zhoufeng.(2024).Rapid Determination of Positive-Negative Bacterial Infection Based on Micro-Hyperspectral Technology.SENSORS,24(2).
MLA Du, Jian,et al."Rapid Determination of Positive-Negative Bacterial Infection Based on Micro-Hyperspectral Technology".SENSORS 24.2(2024).

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。