Combination of time domain-system matrix and x-space methods to reconstruct magnetic particle images with isotropic resolution
文献类型:期刊论文
作者 | Shan, Shihao1; Zhang, Chenglong1; Yin, Lin2![]() ![]() ![]() |
刊名 | PHYSICS IN MEDICINE AND BIOLOGY
![]() |
出版日期 | 2024-02-07 |
卷号 | 69期号:3页码:13 |
关键词 | magnetic particle imaging x-space isotropic resolution time domain system matrix medical image reconstruction |
ISSN号 | 0031-9155 |
DOI | 10.1088/1361-6560/ad19f0 |
通讯作者 | Du, Yang(yang.du@ia.ac.cn) ; Tian, Jie(tian@ieee.org) ; Ma, Xiaopeng(xiaopeng.ma@sdu.edu.cn) |
英文摘要 | Objective. Imaging of superparamagnetic iron oxide nanoparticles based on their non-linear response to alternating magnetic fields shows promise for imaging cells and vasculature in healthy and diseased tissue. Such imaging can be achieved through x-space reconstruction typically along a unidirectional Cartesian trajectory, which rapidly convolutes the particle distribution with a 'anisotropic blurring' point spread function (PSF), leading to images with anisotropic resolution. Approach. Here we propose combining the time domine-system matrix and x-space reconstruction methods into a forward model, where the output of the forward model is the PSF-blurred x-space reconstructed image. We then treat the blur as an inverse problem solved by Kaczmarz iteration. Main results. After we have proposed the method optimization, the normal resolution of simulation and device images has been increased from 3.5 mm and 5.25 mm to 1.5 mm and 3.25 mm, which has reached the level in the tangential resolution. Quantitative indicators of image quality such as PSNR and SSIM have also been greatly improved. Significance. Simulation and imaging of real phantoms indicate that our approach provides better isotropic resolution and image quality than the x-space method alone or other methods for removing PSF blur. Using our proposed method to optimize the image quality of x-space reconstructed images using unidirectional Cartesian trajectories, it will promote the clinical application of MPI in the future. |
WOS关键词 | MODEL |
资助项目 | National Natural Science Foundation of China https://doi.org/10.13039/501100001809[2022CXGC010501] ; Key R&D Program of Shandong Province, China[82227802] ; National Natural Science Foundation of China |
WOS研究方向 | Engineering ; Radiology, Nuclear Medicine & Medical Imaging |
语种 | 英语 |
WOS记录号 | WOS:001144946700001 |
出版者 | IOP Publishing Ltd |
资助机构 | National Natural Science Foundation of China https://doi.org/10.13039/501100001809 ; Key R&D Program of Shandong Province, China ; National Natural Science Foundation of China |
源URL | [http://ir.ia.ac.cn/handle/173211/54783] ![]() |
专题 | 自动化研究所_中国科学院分子影像重点实验室 |
通讯作者 | Du, Yang; Tian, Jie; Ma, Xiaopeng |
作者单位 | 1.Shandong Univ, Sch Control Sci & Engn, Jinan 250061, Shandong, Peoples R China 2.Inst Automat, CAS Key Lab Mol Imaging, Beijing 100190, Peoples R China 3.Shandong Univ, Qilu Hosp, Cheeloo Coll Med, Dept Radiol, Jinan 250012, Shandong, Peoples R China 4.960 Hosp PLA, Dept Nucl Med, 25 Shifan Rd, Jinan 250031, Shandong, Peoples R China 5.Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, D-81337 Munich, Germany 6.Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Sch Engn Med, Beijing 100191, Peoples R China |
推荐引用方式 GB/T 7714 | Shan, Shihao,Zhang, Chenglong,Yin, Lin,et al. Combination of time domain-system matrix and x-space methods to reconstruct magnetic particle images with isotropic resolution[J]. PHYSICS IN MEDICINE AND BIOLOGY,2024,69(3):13. |
APA | Shan, Shihao.,Zhang, Chenglong.,Yin, Lin.,Yang, Xiaoli.,Yu, Dexin.,...&Ma, Xiaopeng.(2024).Combination of time domain-system matrix and x-space methods to reconstruct magnetic particle images with isotropic resolution.PHYSICS IN MEDICINE AND BIOLOGY,69(3),13. |
MLA | Shan, Shihao,et al."Combination of time domain-system matrix and x-space methods to reconstruct magnetic particle images with isotropic resolution".PHYSICS IN MEDICINE AND BIOLOGY 69.3(2024):13. |
入库方式: OAI收割
来源:自动化研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。