A normalized evaluation method on the interface parameters of rubber/cord pull-out tests for different sized samples
文献类型:期刊论文
作者 | Wang CW(王琮文)4,5; Xiao C(肖驰)5; Dai, Yujing3![]() ![]() ![]() ![]() ![]() |
刊名 | ACTA MECHANICA SINICA
![]() |
出版日期 | 2024-03-01 |
卷号 | 40期号:3页码:10 |
关键词 | Rubber Composites Finite element method Cohesive elements H pull-out test |
ISSN号 | 0567-7718 |
DOI | 10.1007/s10409-023-23210-x |
通讯作者 | Huan, Yong(huany@lnm.imech.ac.cn) ; Huan, Yan(huany@ciac.ac.cn) |
英文摘要 | H pull-out test is widely employed as a primary method for estimating the adhesion value of the interface in the rubber/cord composites. However, the current international standards only require to record the pull-out force in rubber/cord H pull-out tests, and emphasize that results obtained from samples of different sizes are not comparable. In this paper, we investigate the comparability of H pull-out results from rubber/cord samples of varying samples and propose an evaluation method to normalize these results. Rubber/cord H pull-out tests of samples with the sizes of 5 mm, 6.4 mm, and 10 mm are undertaken respectively (the results of the specimens with dimensions of 7.5 mm and 8.5 mm are provided as supplementary information). Based on the test results, the adhesion values are analyzed by the model of cohesive elements in finite element method, and the cohesive parameters derived from these models are considered more accurate indicators of adhesion value than the pull-out force. Therefore, a more reasonable comparison of adhesion values becomes feasible. The cohesive parameters are initially determined using the 6.4 mm model and then applied to the other sample models. Good consistency can be seen between the simulations and the test results even though the sample sizes are changing, demonstrating that cohesive parameters remain unaffected by sample dimensions. Based on this, we develop a normalization method that enables the comparability of rubber/cord H pull-out results from samples of different sizes. The cohesive parameters provide a more accurate representation of the adhesion value, and the normalization method we propose serves as an extension of current experimental methods outlined in international standard. |
分类号 | 二类 |
WOS关键词 | MIXED-MODE FRACTURE ; FIBER ; STRENGTH ; COMPOSITE ; STRESS ; TEMPERATURE ; SIMULATION ; PREDICTION ; THICKNESS ; BEHAVIOR |
资助项目 | Strategic Priority Research Program of Chinese Academy of Sciences[XDC06050000] ; National Natural Science Foundation of China[11972037] |
WOS研究方向 | Engineering ; Mechanics |
语种 | 英语 |
WOS记录号 | WOS:001189379200003 |
资助机构 | Strategic Priority Research Program of Chinese Academy of Sciences ; National Natural Science Foundation of China |
其他责任者 | Huan, Yong ; Huan, Yan |
源URL | [http://dspace.imech.ac.cn/handle/311007/94896] ![]() |
专题 | 力学研究所_非线性力学国家重点实验室 |
通讯作者 | Huan Y(郇勇) |
作者单位 | 1.Chinese Acad Sci, Changchun Inst Appl Chem, Polymer Composite Engn Lab, Changchun 130022, Peoples R China 2.Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Polymer Phys & Chem, Changchun 130022, Peoples R China; 3.Beijing Inst Technol, Sch Aerosp Engn, Beijing 100081, Peoples R China; 4.Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China; 5.Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech LNM, Beijing 100190, Peoples R China; |
推荐引用方式 GB/T 7714 | Wang CW,Xiao C,Dai, Yujing,et al. A normalized evaluation method on the interface parameters of rubber/cord pull-out tests for different sized samples[J]. ACTA MECHANICA SINICA,2024,40(3):10. |
APA | 王琮文.,肖驰.,Dai, Yujing.,Wang, Jun.,马寒松.,...&Huan Y.(2024).A normalized evaluation method on the interface parameters of rubber/cord pull-out tests for different sized samples.ACTA MECHANICA SINICA,40(3),10. |
MLA | 王琮文,et al."A normalized evaluation method on the interface parameters of rubber/cord pull-out tests for different sized samples".ACTA MECHANICA SINICA 40.3(2024):10. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。