中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Colorimetric and fluorescent independent dual "signal on" biosensor for accurate detection of ochratoxin A based on aptamer-triggered biocatalytic reactions

文献类型:期刊论文

作者Ding, Hao1; Zhang, Mingdi1; Wang, Xiaochun1; He, Shuai2; Wang, Xiaokun1; Chen, Lingxin3,4,5
刊名ANALYTICA CHIMICA ACTA
出版日期2024-04-22
卷号1299页码:10
关键词Ochratoxin A Dual-channel Signal on In-system correction Mini-program
ISSN号0003-2670
DOI10.1016/j.aca.2024.342440
通讯作者Wang, Xiaokun(wxkun87@126.com)
英文摘要Ochratoxin A (OTA) is a hazardous food contaminant with significant health risks. Dual -channel OTA detection is noted for its cross-reference capability and high accuracy. Still, challenges in addressing in -system corrections and "signal off" related false positives and limited signal gains remain. Herein, we developed a dual -channel "signal on" aptasensor with one recognition process and two independent signal outputs for OTA analysis. The OTA aptamer binds to magnetic beads (MBs) and partially hybridizes with a complementary -trigger (cDNATrigger) sequence. Adding OTA disrupts the duplex sequence, leading to G-quadruplex (G4) formation and enrichment on the MBs, which then interacts with hemin to catalyze a color signal. Concurrently, the freed cDNA-Trigger catalyzes an enzyme -free DNA circuit, producing a fluorescence signal. The magnetic enrichment and signal amplification strategies make the proposed assay demonstrate excellent sensitivity toward OTA, with limits of detection (LOD) of 0.017 pM in the fluorescence channel and 48.1 pM in the colorimetric channel. Both channels have effectively detected OTA in grape juice and baijiu, demonstrating their applicability and reliability. Moreover, given the widespread use of smartphones globally, a mini -program with a self -correction function was designed to facilitate on -site colorimetric channel monitoring, making OTA detection more accessible and user-friendly.
WOS关键词ELISA ; APTASENSOR ; ASSAY
WOS研究方向Chemistry
语种英语
WOS记录号WOS:001209090700001
资助机构National Natural Science Foundation of China
源URL[http://ir.yic.ac.cn/handle/133337/35351]  
专题中国科学院烟台海岸带研究所
通讯作者Wang, Xiaokun
作者单位1.Qingdao Univ Sci & Technol, Coll Marine Sci & Biol Engn, Shandong Prov Key Lab Biochem Engn, Qingdao 266042, Peoples R China
2.Univ New South Wales, Sch Mech & Mfg Engn, Sydney 2052, Australia
3.Chinese Acad Sci, Yantai Inst Coastal Zone Res, Res Ctr Coastal Environm Engn & Technol, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Peoples R China
4.Binzhou Med Univ, Sch Pharm, Yantai 264003, Peoples R China
5.Shaoxing Univ, Coll Chem & Chem Engn, Shaoxing 312000, Peoples R China
推荐引用方式
GB/T 7714
Ding, Hao,Zhang, Mingdi,Wang, Xiaochun,et al. Colorimetric and fluorescent independent dual "signal on" biosensor for accurate detection of ochratoxin A based on aptamer-triggered biocatalytic reactions[J]. ANALYTICA CHIMICA ACTA,2024,1299:10.
APA Ding, Hao,Zhang, Mingdi,Wang, Xiaochun,He, Shuai,Wang, Xiaokun,&Chen, Lingxin.(2024).Colorimetric and fluorescent independent dual "signal on" biosensor for accurate detection of ochratoxin A based on aptamer-triggered biocatalytic reactions.ANALYTICA CHIMICA ACTA,1299,10.
MLA Ding, Hao,et al."Colorimetric and fluorescent independent dual "signal on" biosensor for accurate detection of ochratoxin A based on aptamer-triggered biocatalytic reactions".ANALYTICA CHIMICA ACTA 1299(2024):10.

入库方式: OAI收割

来源:烟台海岸带研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。