中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Modified Jiles-Atherton Model-Based System Matrix Generation Method for Magnetic Particle Imaging

文献类型:期刊论文

作者Li, Yimeng1,2,3; Li, Guanghui1,2,3; Zhang, Peng4; An, Yu1,2,3; Hui, Hui3; Tian, Jie1,2,3
刊名IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
出版日期2024
卷号73页码:9
关键词Coils Magnetization Electromagnetics Image reconstruction Voltage measurement Mathematical models Biomedical imaging Magnetic nanoparticle magnetic particle imaging (MPI) modified Jiles-Atherton (MJA) model system matrix (SM)
ISSN号0018-9456
DOI10.1109/TIM.2024.3381694
通讯作者An, Yu(yuan1989@buaa.edu.cn) ; Hui, Hui(hui.hui@ia.ac.cn) ; Tian, Jie(tian@ieee.org)
英文摘要The system matrix (SM) is an important component of magnetic particle imaging (MPI) because it describes the mapping between the particle concentration and voltage signal. The acquisition of SM predominantly relies on measurement-based calibration. However, the measurement procedure is time-consuming and susceptible to noise interference, leading to a decrease in reconstruction quality. The need for measuring the SM is because existing MPI forward physical process models are not sufficiently accurate for model-based SM generation. To address this problem, we propose a model-based SM generation method based on the modified Jiles-Atherton (MJA) for accurate and fast modeling of the MPI forward physical process (MJA-SMGM). In the proposed method, the MJA accurately describes the dynamic magnetization responses of superparamagnetic iron-oxide (SPIO) nanoparticles. The MJA model considers the relaxation effect to improve accuracy and reduce complexity to accelerate solving. Additionally, time-harmonic electromagnetic field analysis for inhomogeneity and the transfer function of the receive signal chain are included for SM generation. The proposed MJA-SMGM method can achieve fast and accurate SM generation, thereby improving the quality of reconstructed images. Compared to the complex Fokker-Planck method, MJA-SMGM is approximately 70 times faster and reduces error by 30.2% according to the results of homemade MPI scanner experiments. Additionally, the proposed method improves image quality by 2.2 times in terms of the signal-to-noise ratio. These results indicate that MJA-SMGM has the potential to improve the applicability of SM methods in various MPI scanners.
WOS关键词NANOPARTICLE ; RESOLUTION ; SIGNAL
资助项目National Natural Science Foundation of China
WOS研究方向Engineering ; Instruments & Instrumentation
语种英语
WOS记录号WOS:001200475300002
出版者IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
资助机构National Natural Science Foundation of China
源URL[http://ir.ia.ac.cn/handle/173211/58317]  
专题自动化研究所_中国科学院分子影像重点实验室
通讯作者An, Yu; Hui, Hui; Tian, Jie
作者单位1.Beihang Univ, Sch Engn Med, Beijing 100191, Peoples R China
2.Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100191, Peoples R China
3.Chinese Acad Sci, Inst Automat, CAS Key Lab Mol Imaging, Beijing Key Lab Mol Imaging, Beijing 100190, Peoples R China
4.Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Li, Yimeng,Li, Guanghui,Zhang, Peng,et al. Modified Jiles-Atherton Model-Based System Matrix Generation Method for Magnetic Particle Imaging[J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT,2024,73:9.
APA Li, Yimeng,Li, Guanghui,Zhang, Peng,An, Yu,Hui, Hui,&Tian, Jie.(2024).Modified Jiles-Atherton Model-Based System Matrix Generation Method for Magnetic Particle Imaging.IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT,73,9.
MLA Li, Yimeng,et al."Modified Jiles-Atherton Model-Based System Matrix Generation Method for Magnetic Particle Imaging".IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 73(2024):9.

入库方式: OAI收割

来源:自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。