中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Light Source Stability Issues and Measurements in Flux Calibrations for Space Gaze Camera

文献类型:期刊论文

作者C. Lin; N. Zhang; T. Y. Zhang; J. Luo; J. N. Zheng and X. H. Zhang
刊名Photonics
出版日期2022
卷号9期号:12页码:16
DOI10.3390/photonics9120976
英文摘要Flux calibration is an important test item in laboratory calibration experiments of space gaze cameras, which is the basis for obtaining high-precision scientific application data. In the flux calibration of a space gaze camera, the multi-field calibration method is adopted. The instability of the calibration light source will introduce uncertainty during the calibration process. When the spatial camera adopts the gaze imaging mode, the stability of the light source indicates the change in the total energy received by the image plane during the gaze time, which is characterized by relative uncertainty. When the luminous intensity standard lamp runs for the long-term calibration of the stability of the calibration light source, real-time performance and accuracy cannot be guaranteed. Therefore, it is proposed to use a photodetector to measure the stability of the calibration light source for long-term and real-time accurate measurements. First, the stability of the photodetector is calibrated using the light emitting diode; then, the stability of the calibration light source is measured using the photodetector; finally, the stability uncertainty of the calibration light source and the measurement uncertainty of the method is evaluated. The results of the simulation analysis and experimental verification indicate that the gaze time is 5 min and the sampling frequency of the photodetector is 15 Hz; for example, when the flux calibration time is 8 h, the stability uncertainty of the calibration source is 0.42%, and the relative measurement uncertainty is 0.01%.
URL标识查看原文
语种英语
源URL[http://ir.ciomp.ac.cn/handle/181722/67675]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
C. Lin,N. Zhang,T. Y. Zhang,et al. Light Source Stability Issues and Measurements in Flux Calibrations for Space Gaze Camera[J]. Photonics,2022,9(12):16.
APA C. Lin,N. Zhang,T. Y. Zhang,J. Luo,&J. N. Zheng and X. H. Zhang.(2022).Light Source Stability Issues and Measurements in Flux Calibrations for Space Gaze Camera.Photonics,9(12),16.
MLA C. Lin,et al."Light Source Stability Issues and Measurements in Flux Calibrations for Space Gaze Camera".Photonics 9.12(2022):16.

入库方式: OAI收割

来源:长春光学精密机械与物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。