Method for unattended measurement of surface reflectance in field sites

文献类型:期刊论文

作者Z. Xia, S. Wang, X. Yi, Y. Wang and W. Fang
刊名Guangxue Jingmi Gongcheng/Optics and Precision Engineering
出版日期2023
卷号31期号:16页码:2319-2332
ISSN号1004924X
DOI10.37188/OPE.20233116.2319
英文摘要The performance of on-orbit payloads is inevitably degraded. Field calibration is a primary method of on-orbit radiometric calibration for some satellite payloads,and its accuracy mainly depends on how accurate the surface reflectance is. This study introduces the working principle and system composi⁃ tion of the Automatic Observation System of Surface Reflectance,and unattended,automated,and contin⁃ uous spectral surface reflectance measurements were conducted at the Dunhuang Radiation Calibration Field. The short- and long-term stabilities of the surface reflectance data acquired simultaneously were compared and analyzed using the standard whiteboard and irradiance methods,respectively. The surface reflectance is directly traceable to the reflectance of the standard whiteboard,and the data processing meth⁃ od reduces the calibration transfer link. The results are as follows. The mean deviation of short-term mea⁃ surement of the surface reflectance by the standard whiteboard method is 0. 130%. For the long-term mea⁃ surement,the mean deviation of the 350-600 nm band is 4. 996%,and the mean deviation of the 600-2 500 nm band is 2. 104%. The standard whiteboard method is reasonable and feasible for measuring the surface reflectance,and the figure of reflectance is continuous and smooth,and it has less fluctuation. The accuracy of reflectance can be improved by regularly cleaning the standard whiteboard. The short-term measurement of the irradiance method is similar to that of the standard whiteboard method;the mean devi⁃ ation of the 350-1 900 nm band is 0. 236%,and the mean deviation of the 1 900-2 500 nm band is 0. 443%. For the long-term measurement,the overall drift of the reflectance is small,with an average drift of 0. 735%. However,there is a disadvantage of large local noise in the reflectance curve. The two methods can be combined to obtain accurate surface reflectance data. © 2023 Chinese Academy of Sciences. All rights reserved.
URL标识查看原文
源URL[http://ir.ciomp.ac.cn/handle/181722/68038]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Z. Xia, S. Wang, X. Yi, Y. Wang and W. Fang. Method for unattended measurement of surface reflectance in field sites[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2023,31(16):2319-2332.
APA Z. Xia, S. Wang, X. Yi, Y. Wang and W. Fang.(2023).Method for unattended measurement of surface reflectance in field sites.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,31(16),2319-2332.
MLA Z. Xia, S. Wang, X. Yi, Y. Wang and W. Fang."Method for unattended measurement of surface reflectance in field sites".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 31.16(2023):2319-2332.

入库方式: OAI收割