中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Copper-loaded chitosan coating for improved in-vitro corrosion resistance and endothelialization of magnesium alloy stents

文献类型:期刊论文

作者Li, Pengyu2,3; Ma, Jing2; Kang, Shumei3; Chen, Shanshan1,2
刊名MATERIALS CHEMISTRY AND PHYSICS
出版日期2023-09-01
卷号305页码:13
关键词Magnesium alloy Copper-loaded chitosan coating Copper ions Corrosion resistance Endothelial cell
ISSN号0254-0584
DOI10.1016/j.matchemphys.2023.127931
通讯作者Chen, Shanshan(sschen@imr.ac.cn)
英文摘要For degradable magnesium alloy stents, excellent corrosion resistance and rapid endothelialization are two essential properties. In this paper, we plan to use a copper-loaded chitosan coating to accelerate the endothelialization process of the stent, which not only improves the biocompatibility of the magnesium alloy stent, but also its corrosion resistance by improving the service environment in vivo. Copper is an impurity in magnesium alloys, so how copper-containing coatings affect the corrosion resistance of magnesium alloy stents is the focus of this paper. The corrosion properties of the material were characterized by electrochemical experiments, immersion experiments, and in vitro cellular experiments characterized the effect of the copper-loaded coating on endothelial cells. The results showed that the Icorr of the copper-loaded chitosan coated sample and the Icorr of the unloaded copper chitosan coated sample were both in the order of 10-8, and the decrease of the corrosion resistance of the magnesium alloy by the copper-containing chitosan composite coating was not significant, and it still had a protective effect on the magnesium alloy substrate. During the immersion process, magnesium and copper ions were slowly released, followed by the hydrogen released. In addition, the weight loss rate of different coated samples presented the tendency of slower at inital, faster at last, and the weight loss rate of 0.041% for the copper-loaded chitosan coated sample was not significantly different from that of 0.035% for the unloaded copper coating group, after 28 days of immersion. The in vitro degradation products of the copper-loaded composite coating on the surface of magnesium alloy were also analyzed by XRD and EPMA, which included Mg(OH)2, Mg3(PO4)2 and Ca3(PO4)2; in addition the degradation process was analyzed. The cellular experiments results showed that the copper-loaded magnesium alloy had a proliferation rate of 243.0% for endothelial cells, which indicated that the copper-loaded coating could endow magnesium alloy stent a good biofunctional properties.
资助项目National Natural Science Foundation of China[51901227] ; Youth Innovation Promotion Association, Chinese Academy of Sciences[2019194]
WOS研究方向Materials Science
语种英语
WOS记录号WOS:001012424000001
出版者ELSEVIER SCIENCE SA
资助机构National Natural Science Foundation of China ; Youth Innovation Promotion Association, Chinese Academy of Sciences
源URL[http://ir.imr.ac.cn/handle/321006/178381]  
专题金属研究所_中国科学院金属研究所
通讯作者Chen, Shanshan
作者单位1.Chinese Acad Sci, Inst Met Res, Shenyang, Peoples R China
2.Chinese Acad Sci, Inst Met Res, Shi Changxu Innovat Ctr Adv Mat, Shenyang 110016, Peoples R China
3.Univ Sci & Technol Liaoning, Sch Mat & Met, Anshan 114051, Peoples R China
推荐引用方式
GB/T 7714
Li, Pengyu,Ma, Jing,Kang, Shumei,et al. Copper-loaded chitosan coating for improved in-vitro corrosion resistance and endothelialization of magnesium alloy stents[J]. MATERIALS CHEMISTRY AND PHYSICS,2023,305:13.
APA Li, Pengyu,Ma, Jing,Kang, Shumei,&Chen, Shanshan.(2023).Copper-loaded chitosan coating for improved in-vitro corrosion resistance and endothelialization of magnesium alloy stents.MATERIALS CHEMISTRY AND PHYSICS,305,13.
MLA Li, Pengyu,et al."Copper-loaded chitosan coating for improved in-vitro corrosion resistance and endothelialization of magnesium alloy stents".MATERIALS CHEMISTRY AND PHYSICS 305(2023):13.

入库方式: OAI收割

来源:金属研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。